Authors: Li, Xiao-Long; 1 | Xie, Chen-Yi; 1 | Xu, Hui-Xiong; * | Yu, Song-Yuan; *
Affiliations: Interventional Ultrasound Unit, Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Ultrasound Research and Education Institute, Tongji University Cancer Center, Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Tongji University School of Medicine, Shanghai, China
Correspondence: [*] Corresponding authors: Song-Yuan Yu, MD, Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Ultrasound Research and Education Institute, Tongji University Cancer Center, Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Tongji University School of Medicine, No. 301, Yanchang Middle Road, Shanghai 200072, China. Tel.:/Fax: +86 21 66301031; E-mail: [email protected]. Hui-Xiong Xu, MD, PhD, Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Ultrasound Research and Education Institute, Tongji University Cancer Center, Shanghai Engineering Research Center of Ultrasound Diagnosis and Treatment, Tongji University School of Medicine, No. 301, Yanchang Middle Road, Shanghai 200072, China. Tel.:/Fax: +86 21 66301031; E-mail: [email protected].
Note: [1] These authors contributed equally to this article.
Abstract: Pseudoaneurysm (PSA) formation is the most common arterial complication of endovascular procedures requiring arterial puncture. The present study reported a case of a 72-year-old male patient with iatrogenic femoral artery PSA treated with contrast-enhanced ultrasound (CEUS)-guided thrombin injection. Conventional ultrasound (US) and CEUS were used to diagnose, guide treatment, and evaluate the treatment efficacy. In the case, the PSA was successfully occluded with 1000 IU of thrombin. During the follow-up after 48 hours of thrombin injection, US found that the PSA had complete thrombosis without arterial supply. No complications occurrence in the course of the treatment. CEUS-guided thrombin injection for the treatment of PSA was effective and safety and the associated literatures were also reviewed.
Keywords: Contrast-enhanced ultrasound, pseudoaneurysm, thrombin
DOI: 10.3233/CH-200923
Journal: Clinical Hemorheology and Microcirculation, vol. 76, no. 4, pp. 549-557, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]