Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Zhang, Wei-Binga; # | Li, Jing-Jinga; # | Chen, Xiang-Yongb | He, Bei-Lia | Shen, Rong-Huaa | Liu, Huaa | Chen, Jiana | He, Xiao-Feic; *
Affiliations: [a] Department of Medical Ultrasound, Jiangsu Provincial Corps Hospital, Chinese People’s Armed Police Forces, Yangzhou, China | [b] Department of Special Diagnosis, Lushan Rehabilitation Medicine Center, Wuxi Joint Service Forces, Jiujiang, China | [c] Department of Medical Rehabilitation, Jiangsu Provincial Corps Hospital, Chinese People’s Armed Police Forces, Yangzhou, China
Correspondence: [*] Corresponding author: Xiao-Fei He, Department of Medical Rehabilitation, Jiangsu Provincial Corps Hospital, Chinese People’s Armed Police Forces, No. 8, Jiangdu South Road, Yangzhou 225003, China. Tel: +86 514 87232421; E-mail: [email protected].
Note: [#] These authors contributed equally to this work.
Abstract: OBJECTIVES:To compare the diagnostic efficacy of shear wave elastography (SWE) comnined with ACR TI-RADS categories for malignancy risk stratification of thyroid nodules with interminate FNA cytology. METHODS:The clinical data, sonographic features, ACR TI-RADS grading and shear wave elastography images of 193 patients of surgical pathologically proven thyroid nodules with interminate FNA cytology were retrospectively analyzed. The diagnostic efficacy of ACR TI-RADS categories, the maximum Young’s modulus (Emax) of SWE and the combination of the two were calculated respectively. RESULTS:The ROC curves were drawn using surgical pathology results as the gold standard. The ROC curves indicated that the cut-off value of ACR TI-RADS and Emax of SWE was TR5 and 41.2 kPa respectively, and the area under the ROC curve (AUC) was 0.864 (95% CI: 0.879–0.934) and 0.858 (95% CI: 0.796–0.920) respectively. The diagnostic sensitivity, specificity and accuracy of ACR TI-RADS was 81.4% (127/156), 84.8% (31/37), and 81.9% (158/193), respectively. That of SWE Emax was 80.8% (126/156), 78.4% (29/37), and 80.3% (155/193), respectively. After SWE combined with ACR TI-RADS, the sensitivity, specificity and accuracy was 94.2% (147/156), 75.7% (28/37), and 90.7% (175/193), respectively. CONCLUSIONS:ACR TI-RADS classification system and shear wave elastography had high diagnostic efficacy for thyroid nodules with interminate FNA cytology. The combination of the two could improve diagnostic sensitivity and accuracy, and could help to differentiate benign and malignant thyroid nodules with interminate FNA cytology.
Keywords: Thyroid nodules, indeterminate, shear wave elastography, ACR TI-RADS
DOI: 10.3233/CH-200893
Journal: Clinical Hemorheology and Microcirculation, vol. 76, no. 3, pp. 381-390, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]