Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected Presentations held at the 34th Conference of the German Society for Clinical Microcirculation and Hemorheology, Regensburg, Germany, 27–28 November, 2015
Guest editors: L. Prantl, E.M. Jung and F. Jung
Article type: Research Article
Authors: Paprottka, P.M.a; * | Zengel, P.b | Cyran, C.C.a | Paprottka, K.J.a | Ingrisch, M.a | Nikolaou, K.a | Reiser, M.F.a | Clevert, D.A.a
Affiliations: [a] Institute for Clinical Radiology, Ludwig Maximilian University Hospital, Munich, Germany | [b] Institute for Ear, Nose and Throat Medicine, Munich, Germany
Correspondence: [*] Corresponding author: Philipp Marius Paprottka, Institute for Clinical Radiology, Ludwig Maximilian University Hospital, Munich, Marchioninistrasse 15, 81377 Munich, Germany. Tel.: +49 89 7095 3620; Fax: +49 89 7095 8832; E-mail: [email protected]
Abstract: PURPOSE:To evaluate the diagnostic benefits of multimodality imaging using image fusion with magnetic-resonance-imaging (MRI) and contrast-enhanced-ultrasound (CEUS) in an experimental small-animal-squamous-cell-carcinoma-model for the assessment of tissue hemodynamics and morphology. MATERIAL AND METHODS:Human hypopharynx-carcinoma-cells were injected subcutaneously into the left flank of 15 female athymic nude rats. After 10 daysof subcutaneous tumor growth, CEUS and MRI measurements were performed using a high-end-ultrasound-system and 3-T-MRI. After successful point-to-point or plan registration, the registered MR-images were simultaneously shown with the respective ultrasound sectional plane. Data evaluation was performed using the digitally stored video sequence data sets by two experienced radiologists using a subjective 5-point scale. RESULTS:CEUS and MRI are well-known techniques for the assessment of tissue hemodynamics (score: mean 3.8 ± 0.4 SD and score 3.8 ± 0.4 SD). Real-time image fusion of MRI and CEUS yielded a significant (p < 0.001) improvement in score (score 4.8 ± 0.4 SD). Reliable detection of small necrotic areas was possible in all animals with necrotic tumors. No significant intraobserver and interobserver variability was detected (kappa coefficient = +1). CONCLUSION:Image fusion of MRI and CEUS gives a significant improvement for reliable differentiation between different tumor tissue areas and simplifies investigations by showing the morphology as well as surrounding macro-/microvascularization.
Keywords: Image fusion, multimodality imaging, magnetic resonance imaging (MRI), contrast-enhanced ultrasound (CEUS), experimental animal model
DOI: 10.3233/CH-151986
Journal: Clinical Hemorheology and Microcirculation, vol. 61, no. 2, pp. 143-150, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]