Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Schulz, Christiana; 1 | Krüger-Genge, Annea; 2 | Jung, Friedricha; b | Lendlein, Andreasa; b; c; *
Affiliations: [a] Institute of Biomaterial Science and Berlin-Brandenburg Center for Regenerative Therapies, Helmholtz-Zentrum Geesthacht, Teltow, Germany | [b] Helmholtz Virtual Institute – Multifunctional Biomaterials for Medicine, Teltow and Berlin, Germany | [c] Institute of Chemistry, University of Potsdam, Potsdam, Germany
Correspondence: [*] Corresponding author: Andreas Lendlein. E-mail: [email protected].
Note: [1] Present address: Fraunhofer Institute for Cell Therapy and Immunology, Branch Bioanalytics and Bioprocesses (IZI-BB), Potsdam, Germany, at the Institute of Biotechnology, Brandenburg University of Technology Cottbus-Senftenberg, Cottbus – Senftenberg, Germany.
Note: [2] Present address: Department of Anesthesia, Pain Management and Perioperative Medicine, Faculty of Medicine, Dalhousie University, Halifax, Canada.
Abstract: Implantation of synthetic small-diameter vascular bypass grafts is often associated with an increased risk of failure, due to thrombotic events or late intimal hyperplasia. As one of the causes an insufficient hemocompatibility of the artificial surface is discussed. Endothelialization of synthetic grafts is reported to be a promising strategy for creating a self-renewing and regulative anti-thrombotic graft surface. However, the establishment of a shear resistant cell monolayer is still challenging. In our study, cyto- and immuno-compatible poly(ether imide) (PEI) films were explored as potential biomaterial for cardiovascular applications. Recently, we reported that the initial adherence of primary human umbilical vein endothelial cells (HUVEC) was delayed on PEI-films and about 9 days were needed to establish a confluent and almost shear resistant HUVEC monolayer. To accelerate the initial adherence of HUVEC, the PEI-film surface was functionalized with an aptamer-cRGD peptide based endothelialization supporting system. With this functionalization the initial adherence as well as the shear resistance of HUVEC on PEI-films was considerable improved compared to the unmodified polymer surface. The in vitro results confirm the general applicability of aptamers for an efficient functionalization of substrate surfaces.
Keywords: Aptamer, endothelialization, physical functionalization, poly(ether imide) films, shear resistance
DOI: 10.3233/CH-190775
Journal: Clinical Hemorheology and Microcirculation, vol. 75, no. 2, pp. 201-217, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]