Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected Papers of the Joint Conference of the ESCHM-ISCH-ISB-2018, 2-6 July, 2018, Krakow, Poland
Guest editors: F. Jung and M. Fornal
Article type: Research Article
Authors: Putz, Franz J.a; * | Verloh, Niklasd | Erlmeier, Annad | Schelker, Roland C.b | Schreyer, Andreas G.d | Hautmann, Matthias G.c | Stroszczynski, Christiand | Banas, Bernharda | Jung, Ernst M.d
Affiliations: [a] Department of Nephrology, University Hospital Regensburg, Regensburg, Germany | [b] Department of Internal Medicine III, Hematology and Oncology, University Hospital Regensburg, Regensburg, Germany | [c] Department of Radiotherapy, University Hospital Regensburg, Germany | [d] Department of Radiology and Interdisciplinary Ultrasound Department, University Hospital Regensburg, Regensburg, Germany
Correspondence: [*] Corresponding author: Dr. med. Franz Josef Putz, Department of Nephrology, University Hospital Regensburg, Regensburg, Germany. Tel.: +49 941 944 7301; Fax: +49 941 944 7302; E-mail: [email protected].
Abstract: AIM:To assess the influence of difficult examination conditions onto the diagnostic performance of CEUS (contrast-enhanced ultrasound) in focal liver lesions (FLL). METHODS:77 liver CEUS examinations of 75 patients were analysed retrospectively. CEUS was performed as the first diagnostic procedure by one experienced sonographer after bolus injection of 1.0 up to 2.4 ml sulphur hexafluoride microbubbles using a high-end ultrasound device with a high resolution multifrequency probe (1–6 MHz). The combination of complementary imaging (CT or MRI), histology and CEUS follow up of at least 6 months was considered. Cross tables were used to define the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy. Chi-Square Test analysed categorical data. RESULTS:The patients were between 18 and 84 years old (mean 62±11 years). 26 patients suffered from liver cirrhosis (33.8%). 52 patients (67.5%) received therapy for an oncological disease. The final diagnosis showed 52 malignant FLLs including 24 hepatocellular carcinomas (HCCs), 9 cholangiocellular carcinomas (CCCs) and 19 metastases from different primary tumors. In the other 25 patients no malignant lesions could be detected, three of them presenting however liver haemangioma and two of them liver cysts. The overall lesions’ size according to the CEUS findings ranged from 7 to 100 mm (mean 31.1±22.6 mm). Under good examination conditions the malignant potential of a tumor was diagnosed correctly by CEUS in 98.0% of cases (Sensitivity 97.1%, Specificity 100%, PPV 100%, NPV 94.1%, diagnostic accuracy 98.0%). Limited examination conditions (e.g. obesity, meteorism) were present in 35.1% of cases with a decrease of the diagnostic accuracy to 92.6% (Sensitivity 100%, Specificity 77.8%, PPV 90.0%, NPV 100%). CONCLUSION:Despite the influence of difficult examination conditions, CEUS is – in the hands of an experienced sonographer – an excellent diagnostic procedure for the assessment of liver lesions.
Keywords: CEUS, liver imaging, interdisciplinary ultrasound department, examination conditions, tumor
DOI: 10.3233/CH-189417
Journal: Clinical Hemorheology and Microcirculation, vol. 71, no. 2, pp. 267-276, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]