Abstract: AIM:Aim of this study was to firstly describe reproducible, objective perfusion parameters of contrast-enhanced ultrasound (CEUS) kinetics of parathyroid gland adenoma (PA) using perfusion analysis software (VueBox®, Bracco, Italy). Thereby the efficiency of quantitative CEUS for characterization of PA should be evaluated comparing US to postoperative histopathological findings after PA resection. MATERIAL AND METHODS:42 patients with symptoms/lab work suggestive of pHPT presented a parathyroid gland lesion in B-mode US, which was consequently analyzed by dynamic CEUS. CEUS was performed by one experienced examiner after i.v.-injection of max. 2.4 ml sulphurhexaflouride microbubbles saving digital DICOM cine loops (up to 25 s) and images. PA were evaluated during arterial, venous and late phase (up to 3 min.) for perfusion characterization. A retrospective, blinded VueBox® perfusion analysis of arterial phase of 28/42 PA was performed by a second, independent examiner placing 3 ROIs manually in the PA (center, rim of PA, surrounding thyroid gland tissue) to objectify findings. US findings were correlated to postoperative histology after PA resection. RESULTS:Out of 42 patients with PA findings in CEUS, perfusion analysis could be performed in 28/42 cases only as some CEUS cine loops had too much moving. In three cases the second examiner could not detect PA retrospectively, in 25 cases PA were characterized correctly resulting in a sensitivity rate of 89.3 %. VueBox® perfusion analysis confirmed that PA present a persisting hypervascularization of the rim with higher TTP (mean 7.93 s centrally, 8.36 s rim-sided), mTT (mean 56.6 s centrally, 64.5 s rim-sided) and lower PE (mean 10542.93 rm2 centrally, 8909.21 rm2 rim-sided) peripherally followed by a central wash-out during later phases. RT was comparable in all defined regions. CONCLUSION:VueBox® analysis of parathyroid gland CEUS examinations seemed to be a valuable tool for quantification of a PA’s perfusion and can help to detect and localize hyperfunctional parathyroid glands prior to surgery.
Keywords: Contrast-enhancend ultrasonography, 99mTechnetium-sestamibi scintigraphy, diagnostics of primary hyperparathyroidism, VueBox® , CEUS perfusion quantification, parathyroid gland adenoma
DOI: 10.3233/CH-189307
Journal: Clinical Hemorheology and Microcirculation, vol. 70, no. 4, pp. 423-431, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]