Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Special Issue in Honour of the Editor-in-Chief Prof. Dr. Ing. Friedrich Jung on his 70th Birthday
Article type: Research Article
Authors: Saemann, Lars; * | Wenzel, Folker
Affiliations: Faculty Medical and Life Science, Furtwangen University, Villingen-Schwenningen, Germany
Correspondence: [*] Corresponding author: Lars Saemann, Bahnhofstraße 32A, 21398 Neetze, Germany. Tel.: +49 157 858 52 859; E-mail: [email protected].
Abstract: BACKGROUND:Cutaneous microcirculation (cMC) is influenced by many factors. In cardiac surgery, most operations are performed with a cardiopulmonary bypass (CPB) and cardiac arrest induced by cardioplegic solutions. OBJECTIVES:Aim of this study was to examine a correlation between cMC and hemodynamic parameters in patients undergoing heart surgery with two different cardioplegic solutions. METHODS:20 patients were included and divided into Histidine-Tryptophane-α-Ketoglutarate solution- (HTK, n = 10) and blood cardioplegia- (BCP, n = 10) groups. With initiation of CPB, cMC was continuously monitored with Laser-Doppler-Perfusion (LDP) until termination of CPB. Additionally, we measured hemoglobin-concentration (HbC) with a Blood-Parameter-Monitoring-System. RESULTS:LDP pulsation was almost equal before and after CPB and decreased during aortic cross clamping. The following factors influenced LDP: central venous pressure (CVP), mean arterial pressure (MAP), total peripheral resistance (TPR) and flow of the heart-lung machine. We measured relative LDP and HbC (RLDP; RHbC). Five and 25 min after administration of cardioplegia, RLDP (1.22±0.8; 1.17±0.94) and RHbC (0.92±0.06; 0.96±0.09) in the HTK-group were lower than in the BCP-group: RLDP (1.58±1.11; 1.58±2.2) and RHbC (1.00±0.05; 0.99±0.13). HTK-patients with a body surface area (BSA) <2 m2 showed a lower RLDP (0.75±0.50), than patients over 2 m2 (RLDP = 1.64±0.97). CONCLUSIONS:The cMC is influenced by CPB. Cutaneous LDP monitoring is a non-invasive method, for estimating hemodynamics intraoperatively.
Keywords: Extracorporeal circulation, heart-lung machine, microcirculation, Laser-Doppler-Perfusion, Laser-Doppler-Flow, cardiopulmonary bypass, Calafiore, Bretschneider, cardioplegia, hemodynamics
DOI: 10.3233/CH-189102
Journal: Clinical Hemorheology and Microcirculation, vol. 69, no. 1-2, pp. 13-21, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]