Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Gayda, Mathieu; ; | Gremeaux, Vincent; ; ; ; | Drigny, Joffrey; | Juneau, Martin; ; | Nigam, Anil; ;
Affiliations: Cardiovascular Prevention and Rehabilitation Centre (ÉPIC), Montreal Heart Institute and ”Université de Montréal“, Montreal, QC, Canada | Research Center, Montreal Heart Institute and ”Université de Montréal“, Montreal, QC, Canada | Department of Medicine, Faculty of Medicine, ”Université de Montréal“, Montreal, Canada | INSERM - U1093 “Cognition, Action, et Plasticité Sensorimotrice”, Dijon, France | Plateforme d'Investigation Technologique, CIC Inserm 1432, CHU de Dijon, 23 rue Gaffarel, 21079 Dijon, France
Note: [] Corresponding author: Mathieu Gayda, Ph.D, Cardiovascular Prevention and Rehabilitation Centre (Centre ÉPIC), Montreal Heart Institute and Université de Montréal, 5055 St-Zotique Street East, Montreal, QC H1T 1N6, Canada. Tel.: +1 514 374 1480/Ext 4208; Fax: +1 514 374 2445; E-mail: [email protected]
Abstract: This study aims were: 1) to assess forearm blood flow (FBF) and muscle oxygen consumption (mVO2) repeatability assessed with near-infra red spectroscopy (NIRS) during venous occlusions (VO) in middle aged healthy subjects and patients with stable coronary heart disease (CHD), 2) to assess the agreement between mVO2 calculated from NIRS signals during VO and arterial occlusion (AO) in 18 middle aged healthy subjects and 12 patients with CHD. FBF and mVO2 were measured using NIRS during 2 successive VO (1-min duration), followed by a 5-min AO. Repeatability for FBF and mVO2 during VO was assessed with intra class correlation (ICC), coefficient of variation (CV %) and agreement between VO and AO mVO2 was assessed with a Bland and Altman analysis. FBF and mVO2 during VO were highly reproducible in healthy (FBF: ICC 0.73, CV% 9.75; mVO2: ICC 0.89, CV% 12.6) and CHD subjects (FBF: ICC 0.95, CV% 10.26; mVO2: ICC 0.98, CV% 7.92). VO and AO mVO2 were in agreement in healthy (mean bias: 0.002 mL O2.min−1.100g−1) and CHD subjects (mean bias: 0.014 mL O2.min−1.100g−1). FBF and mVO2 measured with NIRS during VO and/or AO are highly reproducible methods to assess microvascular function in healthy subjects and stable CHD patients.
Keywords: Near-infra red spectroscopy, repeatability, agreement, vascular occlusions, healthy middle aged subjects, patients with coronary heart disease
DOI: 10.3233/CH-141836
Journal: Clinical Hemorheology and Microcirculation, vol. 59, no. 2, pp. 177-183, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]