Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Niessen, C. | Beyer, L.P. | Haimerl, M. | Schicho, A.; * | Stroszczynski, C. | Wiggermann, P. | Jung, E.M.
Affiliations: Institute for Radiology, University Hospital Regensburg, Regensburg, Germany
Correspondence: [*] Corresponding author: Dr. Andreas Schicho, University Hospital Regensburg, Institute for Radiology, Franz-Josef Strauss Allee 11, 93053 Regensburg, Germany. Tel.: +49 941 944 17409; Fax: +49 941 944 74 11; E-mail: [email protected].
Abstract: PURPOSE:To assess the postprocedure findings after percutaneous irreversible electroporation (IRE) of hepatocellular carcinoma (HCC) in contrast-enhanced ultrasound (CEUS). MATERIALS AND METHODS:Percutaneous IRE was performed in a total of 22 patients with 24 HCC tumours following interdisciplinary tumour board review. The lesions were documented using CEUS before, immediately and within 24 hours after IRE. During follow-up CEUS was performed at 6 weeks and 3, 9, and 12 months after ablation. Two experienced radiologists evaluated the acquired CEUS image date in a consensus reading. RESULTS:Median tumour size before treatment was 13.7±4.8 mm (short axis) and 16.0±5.2 mm (long axis). All HCC lesions showed arterial hyperenhancement in CEUS. Median size of the ablation defect after ablation was 29.3±5.2 mm (short axis) and 31.6±5.6 mm (long axis). After IRE all tumours showed complete devascularization. The size of the ablation defects showed significant shrinkage and reduced peripheral enhancement in the course of follow-up. At 12 months follow-up the ablation defect size decreased to 16.7±4.3 mm (short axis) and 18.3±4.1 mm (long axis). CONCLUSION:CEUS showed a complete devascularization of HCC tumours after IRE. Post-intervetional peripheral enhancement returned to normal during follow-up and may represent zones of reversible damage of cellular integrity through electroporation. A significant shrinkage of the ablation defects during 12 month of follow-up was seen in all cases.
DOI: 10.3233/CH-180449
Journal: Clinical Hemorheology and Microcirculation, vol. 72, no. 1, pp. 85-93, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]