Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Maddison, Liivi | Riigor, Kairi Marie | Karjagin, Juri | Starkopf, Joel
Affiliations: Department of Anaesthesiology and Intensive care, University of Tartu, Tartu University Hospital, Tartu, Estonia
Note: [] Corresponding author: Liivi Maddison, MD, Department of Anaesthesiology and Intensive care, University of Tartu, Tartu University Hospital, Puusepa 8, 51014 Tartu, Estonia. Tel.: +3727318405; Fax: +3727318409; E-mail: [email protected]
Abstract: BACKGROUND: Microvascular alterations and intra-abdominal hypertension are both involved in development of organ failure. It is not known whether increased intra-abdominal pressure (IAP) is associated with microcirculatory perfusion derangements. HYPOTHESIS: Transient increase in IAP induced by pneumoperitoneum affects sublingual microcirculation. METHODS: 16 laparoscopic cholecystectomy patients were studied. Sidestream dark field (SDF) imaging was used to evaluate sublingual microcirculation. Microcirculatory videos were done before surgery, at least 15 minutes after initiation of pneumoperitoneum and 1 hour after the pneumoperitoneum. Microcirculation cut-off value for vessels was 20 μm. RESULTS: IAP was held at 12.6 (from 12 to 14) mmHg, mean (SD) duration of pneumoperitoneum was 41 (14) minutes. At the baseline, mean total vascular density was 18.8 (2.6) and perfused vessel density 13.2 (2.9) per mm2. Proportion of perfused vessels was 59 (11) % and microvascular flow index 2.2 (0.4). Median (IQR) heterogeneity index was 0.6 (0.4–0.9) and mean De Backer score 13.6 (1.5). Increase in IAP did not cause significant changes in sublingual microcirculatory parameters. CONCLUSIONS: Transiently increased IAP due to pneumoperitoneum does not affect sublingual microcirculatory blood flow and vessel density in patients undergoing laparoscopic surgery. However, the low proportion of perfused vessels indicates the prevalence of perioperative microcirculatory deficiency in these patients.
Keywords: Microcirculation, intra-abdominal pressure, laparoscopic surgery, intra-abdominal hypertension, SDF imaging
DOI: 10.3233/CH-131791
Journal: Clinical Hemorheology and Microcirculation, vol. 57, no. 4, pp. 367-374, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]