Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected articles of the 32nd Annual Conference of the German Society for Clinical Hemorheology and Microcirculation, Dresden, Germany, 24 – 25 May, 2013
Article type: Research Article
Authors: Agha, A. | Jung, E.M. | Janke, M. | Hornung, M. | Georgieva, M. | Schlitt, H.J. | Schreyer, A.G. | Strosczcynski, C. | Schleder, S.
Affiliations: Department of Surgery, University Hospital Regensburg, Regensburg, Germany | Department of Radiology, University Hospital Regensburg, Regensburg, Germany
Note: [] A. Agha and E.M. Jung have contributed equally to this manuscript.
Note: [] A. Agha and E.M. Jung have contributed equally to this manuscript.
Note: [] Corresponding author: Dr. med. Stephan Schleder, University Hospital Regensburg, Germany, Department of Radiology, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany. E-mail: [email protected]
Abstract: To evaluate the impact of high-resolution contrast-enhanced ultrasound (CEUS), Color Coded and Power Doppler Sonography (CCDS/PD), in the preoperative recognition of thyroid adenomas. A total of 64 patients (36 female, median age 54 years) underwent surgery for thyroid adenoma. CEUS with linear multifrequency probes (6–9 or 6–15 MHz) and CCDS/PD was performed in all patients preoperatively by an experienced examiner and images were stored in PACS. Reading of the ultrasound images was performed in consensus by two experienced radiologists. Histopathology was achieved as standard of reference in all patients. Median diameter of the tumor lesions was 27 mm. 31 nodules were found on the left side. In B-Scan mode 13 (20%) adenomas showed complex cystic echo pattern and 44 (69%) had a complete and sharp hypoechoic edge. 43 (67%) thyroid adenomas had strong hypervascularization in CCDS/PD. In 61 (95%) adenomas early contrast enhancement was present in CEUS and 50 (78%) adenomas proved no wash-out or central wash-out with persisting edge enhancement. In 47 (73%) cases early contrast enhancement was combined with no washout or with central wash-out with persisting edge enhancement. 45 (70%) thyroid lesions had preoperatively been classified as benign lesions correctly. Dynamic evaluation of microcirculation by CEUS and CCDS/PD enables a more reliable preoperative characterization of thyroid adenomas.
Keywords: CEUS, power doppler, ultrasound, thyroid adenoma
DOI: 10.3233/CH-131777
Journal: Clinical Hemorheology and Microcirculation, vol. 55, no. 4, pp. 403-409, 2013
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]