Abstract: There is increasing evidence in the literature that preoperative treatment with levosimendan optimizes cardiopulmonary haemodynamics in patients scheduled for the implantation of a Left Ventricular Assist Device (LVAD). The present case report describes changes in sublingual microcirculation using incident dark field video microscopy in a patient, who received a continuous infusion of 0.5 mg/h levosimendan 12 h before LVAD implantation. Despite no evident macrohaemodynamic or metabolic changes, there was a dramatic reduction in total vessel density and perfused vessel density suggesting a deterioration of microcirculation according to the consensus conference criteria in vessels smaller than 20 μm in diameter. However, the microcirculation of all visible vessels (regardless of diameter) was maintained. This potential misinterpretation is explained by a levosimedan-induced vasodilation and the subsequent reduction of the percentage of vessels with a diameter smaller than 20 μm. Physicians should carefully consider this pitfall of applying the consensus conference criteria in vasodilator-treated patients.
Keywords: Consensus, diagnostic errors, microcirculation, myocardial diseases, secondary, simendan, vasodilation
DOI: 10.3233/CH-170315
Journal: Clinical Hemorheology and Microcirculation, vol. 68, no. 1, pp. 83-87, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]