Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Developments in the application of high resolution ultrasound in clinical diagnostics
Article type: Research Article
Authors: Ji, Chen-Lia; b | Li, Xiao-Longa | He, Ya-Pinga | Li, Dan-Dana | Gu, Xin-Gangb | Xu, Hui-Xionga; *
Affiliations: [a] Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, Shanghai, China | [b] Department of Medical Ultrasound, Shanghai Putuo District Central Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, China
Correspondence: [*] Corresponding author: Hui-Xiong Xu, MD, PhD, Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine, No. 301, Yanchangzhong Road, Shanghai, 200072, China. Tel.: +86 21 66301031; E-mail: [email protected].
Abstract: PURPOSE: To investigate the correlation between quantitative parameters on contrast-enhanced ultrasound (CEUS) and pathological prognostic factors in patients with breast invasive ductal carcinomas (IDCs). MATERIALS AND METHODS: 102 patients with pathologically proven IDCs were retrospectively enrolled and all were preoperatively evaluated by CEUS. Quantitative analysis was conducted using the SonoLiver® software. On the parametric imaging, the data of rise time (RT), time to peak (TTP), mean transit time (mTT) and maximum intensity (IMAX) were recorded. Pathological prognostic factors, including histological grade, tumor diameter, lymph node status, estrogen receptor (ER), progesterone receptor (PR), C-erb-B2 and Ki-67 expression were evaluated. Correlation of enhancement parameters with pathological prognostic factors was analyzed. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance and operator consistency was evaluated. RESULTS: The RTs and TTPs for lower grade IDCs (grade I or II) and higher histological grade IDCs (grade III) were 9.3 s±3.9 vs. 11.4 s±5.4 (p = 0.016), 11.6 s±6.1 vs. 14.7 s±7.7 (p = 0.028), respectively. The RTs for positive-C-erbB-2 expression and negative-C-erbB-2 expression IDCs were 10.1 s±4.5 vs. 11.9 s±6.0 (p = 0.047). The IMAX showed statistical difference between IDCs with negative-ER and those with positive-ER (p = 0.003), as well as IDCs with negative-PR and those with positive-PR (p = 0.019). The ROC analysis showed that, for the differentiation ER expression, the cut-off point for IMAX was 648.8% with an Az value of 0.718 (95% CI: 0.599–0.836), and the sensitivity and specificity were 63.6% and 70.2% respectively. The intra-operator consistency of the RT, TTP, mTT and IMAX were excellent with an overall ICC of 0.893, 0.858, 0.984 and 0.800, respectively (all p < 0.001). CONCLUSIONS: Quantitative analysis of CEUS may be a useful and objective method in predicting pathological prognostic factors in breast IDCs.
Keywords: Breast, invasive ductal cancer, contrast-enhanced ultrasound, quantitative analysis, conventional ultrasound, prognostic factor, immunohistochemical biomarker
DOI: 10.3233/CH-170251
Journal: Clinical Hemorheology and Microcirculation, vol. 66, no. 4, pp. 333-345, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]