Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected papers of the 18th European Conference for Clinical Hemorheology and Microcirculation (ESCHM), 5-8 June, 2016, Lisbon, Portugal
Article type: Research Article
Authors: Varlet-Marie, Emmanuellea; b | Joré, Célineb; d | Brun, Jean-Frédéricc; *
Affiliations: [a] Institut des Biomolécules Max Mousseron (IBMM) UMR CNRS 5247, Université de Montpellier, Ecole Nationale Supérieure de Chimie de Montpellier, France | [b] Laboratoire de Biophysique & Bio-Analyses, Faculté de Pharmacie, Université de Montpellier, France | [c] UMR CNRS 9214-Inserm U1046 ⪡ Physiopathologie & Médecine Expérimentale du Cœur et des Muscles – PHYMEDEXP ⪢, Unité d’Explorations Métaboliques (CERAMM), Université de Montpellier, Département de Physiologie Clinique, Hôpital Lapeyronie CHU Montpellier, France | [d] Laboratoire des Courses Hippiques, Verrières le Buisson, France
Correspondence: [*] Corresponding author: Jean-Frédéric Brun, UMR CNRS 9214-Inserm U1046 ⪡ Physiopathologie & Médecine Expérimentale du Cœur et des Muscles – PHYMEDEXP ⪢, Unité d’Explorations Métaboliques (CERAMM), Université de Montpellier, Département de Physiologie Clinique, Hôpital Lapeyronie CHU Montpellier, France. Tel.: +33 467338284; Fax: +33 467338986; E-mail: [email protected].
Abstract: Bioelectrical impedancemetry (BIA) has been used to evaluate hematocrit and red cell aggregability in vitro but whole body impedance measurements are also correlated to some hemorheologic factors, suggesting a relationship between viscosity factors and electric properties of blood. We repeatedly reported correlations with whole body BIA and hematocrit, whole blood viscosity and plasma viscosity, red cell rigidity and RBC aggregation. The SBIA Inbody 770 modelizes body as 5 cylinders and measures impedance at 1, 5, 50, 250, 500, and 1000 kHz. With the SBIA we found that hematocrit is best correlated to leg reactance at 50 kHz but also to leg impedance at 1 and 5 kHz and trunk reactance. RBC aggregation “M” is best correlated to arm reactance at 5 kHz but also to most measurements of segmental impedance (28 correlations found). RBC aggregation “M1” is best correlated to arm reactance at 5 kHz and to 19 other impedance measurements. A predictive equation for “M” from the mean between the two arm reactances at 5 kHz (maXc5) is found: M = 2.1845maXc5-23.958 (r = 0.665, p < 0.001) that provides a satisfactory Bland-Altman plot (mean difference: 0.000524 range [–1.6;+1.6]. This study suggests that previously reported correlations between BIA and viscosity factors were not spurious, and that in a narrow cylinder such as the arm the structure of circulating blood (hematocrit, red cell aggregation) may influence the passage of an electric current by increasing reactance.
Keywords: Segmental bioelectrical impedance, hematocrit, myrenne aggregometer, red blood cell aggregation, electrical conductance, light transmission
DOI: 10.3233/CH-168041
Journal: Clinical Hemorheology and Microcirculation, vol. 64, no. 4, pp. 603-611, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]