Issue title: Selected papers of the 18th European Conference for Clinical Hemorheology and Microcirculation (ESCHM), 5-8 June, 2016, Lisbon, Portugal
Article type: Research Article
Authors: Basarab, M.A.a; * | Basarab, D.A.b | Konnova, N.S.c | Matsievskiy, D.D.d | Matveev, V.A.e
Affiliations: [a] Theoretical Informatics and Computer Technologies, Bauman Moscow State Technical University, Moscow, Russia | [b] Department of Cardiovascular Surgery, St.Ioasaf’s Belgorod Regional Hospital, Belgorod, Russia | [c] Sector of Fundamental Problems of Control and Information Systems, Bauman Moscow State Technical University, Moscow, Russia | [d] Research Institute on General Pathology and Pathophysiology, Moscow, Russia | [e] Department of Informatics and Control Systems, Bauman Moscow State Technical University, Moscow, Russia
Correspondence: [*] Corresponding author: M.A. Basarab, Professor, Chair of Theoretical Informatics and Computer Technologies, Bauman Moscow State Technical University, 105005, Vtoraya Baumanskaya str., 5, Moscow, Russia. Tel.: +74992636936; Fax: +74952674844; E-mail: [email protected].
Abstract: OBJECTIVE: The aim of this work was to develop a novel technique for digital processing of Doppler ultrasound blood flow sensor data from noisy blood flow velocity waveforms. METHODS: To evaluate the fluctuating blood flow parameters, various nonlinear dynamics methods and algorithms are often being used. Here, for identification of chaotic and noise components in a fluctuating coronary blood flow, for the first time the Allan variance technique was used. Analysis of different types of noises (White, Brownian, Flicker) was carried out and their strong correlation with fractality of time series (the Hurst exponent) was revealed. RESULTS: Based on a specialized software realizing the developed technique, numerical experiments with real clinical data were carried out. Recommendations for identification of noisy patterns of coronary blood flow in normal and pathological states were developed. CONCLUSION: The methodology gives us the possibility for the more detailed quantitative and qualitative analysis of a noisy fluctuating blood flow data.
Keywords: Blood flow, Doppler flowmetry, Allan variance, Hurst exponent, nonlinear dynamics, Alavar
DOI: 10.3233/CH-168011
Journal: Clinical Hemorheology and Microcirculation, vol. 64, no. 4, pp. 921-930, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]