Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Preibsch, Heikea | Keymel, Stefanieb | Kelm, Malteb | Baars, Theodorc; d; 1 | Kleinbongard, Petrad; 1; *
Affiliations: [a] Department of Radiology, Diagnostic and Interventional Radiology, University Hospital Tuebingen, Tuebingen, Germany | [b] Medical Clinic B, Cardiovascular Research Lab, Medical Faculty, Department of Cardiology, Pneumology and Vascular Diseases, University Hospital Duesseldorf, Duesseldorf, Germany | [c] Clinic of Cardiology, West German Heart and Vascular Centre Essen, Medical School, University of Essen, Essen, Germany | [d] Institute of Pathophysiology, West German Heart and Vascular Centre Essen, University of Essen Medical School, Germany
Correspondence: [*] Corresponding author: Priv. Doz. Dr. rer. nat. Petra Kleinbongard, Institut für Pathophysiologie, Westdeutsches Herz- und Gefäßzentrum, Universitätsklinikum Essen, Hufelandstrasse 55, 45122 Essen, Germany. Tel.: +49 201 723 2763; Fax: +49 201 723 4481; E-mail: [email protected].
Note: [1] These authors contributed equally.
Abstract: BACKGROUND: Red blood cell (RBC) aggregation influences blood flow properties, impacts blood microcirculation and consequently oxygen delivery. Different methods are established to determine RBC aggregation: under static conditions (i.e. the RBC adhesiveness/aggregation test (EAAT)) or under shear conditions (i.e. the laser-assisted optical rotational cell analyzer (LORCA)). OBJECTIVE: Comparison of these two different methods in detecting the RBC aggregation of patients with coronary artery disease (CAD) and of healthy controls. METHODS: RBC aggregation was quantified in peripheral venous blood of patients with CAD and healthy controls using EAAT and LORCA. RESULTS: Both methods detected an increased RBC aggregation in patients with CAD compared to the healthy control group: the ratio of clot-free area to whole area (rCFA) detected with EAAT (15.65 vs. 11.30%), and aggregation index (66.33 vs. 53.90%), shear rate of disaggregation (SDA) (105.59 vs. 69.21 s–1), and upstroke/ttop (0.03 vs. 0.02 au/s) detected with LORCA device were increased, aggregation half time (detected with LORCA) was decreased (2.11 vs. 3.60 s). rCFA (EAAT) correlated with SDA (LORCA). CONCLUSIONS: Both methods determine an increased RBC aggregation in patients with CAD. However, only one measurement parameter of the LORCA seems to reflect the same RBC aggregation properties as the EAAT.
Keywords: Coronary artery disease, measurement devices, red blood cell aggregation
DOI: 10.3233/CH-16201
Journal: Clinical Hemorheology and Microcirculation, vol. 65, no. 4, pp. 363-371, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]