Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Zhao, Lianb; * | Kaewprayoon, Waraporna | Zhou, Hongb | Georgieva, Radostinaa | Bäumler, Hansa; *
Affiliations: [a] Charité-Universitätsmedizin Berlin, Institute of Transfusion Medicine, Berlin, Germany | [b] Institute of Transfusion Medicine, Academy of Military Medical Sciences, Beijing, China
Correspondence: [*] Corresponding author: Lian Zhao, Institute of Transfusion Medicine, Academy of Military Medical Sciences, Beijing, China. Tel.: +86 1066931969; E-mail: [email protected] and Hans Bäumler, Charité-Universitätsmedizin Berlin, Institute of Transfusion Medicine, 10117 Berlin, Germany. Tel.: +49 30450525131; E-mail: [email protected].
Abstract: The impact of macromolecules on RBC aggregation continues to be of interest, nevertheless present measurements still have limitations and need improvement. We applied flow cytometry to measure RBC aggregation in dextran T500 (Dx500) solution. The samples were fixed in the aggregated state by glutaraldehyde. Fixed RBC exhibit auto fluorescence, which can be detected by flow cytometry. Single cells, doublets, triplets and larger aggregates can be distinguished quantitatively and quickly due to the correlation between auto fluorescence intensity and number of RBC per measured event. With the increase in concentration of Dx500, percentages of all aggregates and bigger aggregates increased significantly at concentration of 2%, 4% and 6%, while decreased when the concentration reached 8% and 10%. The percentage of bigger aggregates in concentration of 4% was higher than that in 2% and 6%. The data of flow cytometry was confirmed by microscopic observation and are in good agreement with the literature. The method provide additional advantages to the conventional measurement of RBC aggregation. It gets the distribution of single cells and aggregates as derived from the microscopic observation with hematocrit of physiological level. It uses sample volume as 1/5∼1/10 as needed in sendimentation and photometricmethods.
Keywords: RBC aggregation, dextran, flow cytometry
DOI: 10.3233/CH-15121
Journal: Clinical Hemorheology and Microcirculation, vol. 65, no. 1, pp. 93-101, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]