Abstract: The aim of the present investigation is to evaluate the measurement of plasma viscosity, carried out by tube capillary viscometer and to compare the results with those of the dynamic apparent viscosity, determined by standardized rotational viscometer. The study was carried out in 28 clinically healthy volunteers. Gravity force capillary viscometers of Ubbelohde type were worked out in the laboratory for the purpose of the study. Simultaneous measurement of plasma viscosity was performed with the rheometer LS 30 Contraves with diameters of cylinders φ1 = 11 mm, φ2 = 12 mm, h = 8 mm, and the shear rates varying from 0.017 to 128.5 s−1. All rheological measurements were carried out at 37°C. Certain nonlinearity at the low shear rate range is displayed when the plasma dynamic viscosity is measured by rotational viscometer. The mean plasma viscosity values vary between 3.15 mPa.s at 0.0237 s−1 to 1.34 mPa.s at 128.5 s−1. The mean values of the dynamic plasma viscosity, estimated by capillary viscometer are 1.34 ± 0.05 mPa.s. The viscosity values obtained with the capillary viscometer are slightly lower than those obtained with the Couette viscometer. This phenomenon is probably due to surface adsorbed proteins resulting in spuriously high torque.
Keywords: Ubbelohde viscometry, Couette viscometer, plasma viscosity
DOI: 10.3233/CH-1995-15106
Journal: Clinical Hemorheology and Microcirculation, vol. 15, no. 1, pp. 45-52, 1995
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]