Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Gustavsson, Carl Gunnar | Persson, Sylvi U. | Larsson, Hans | Persson, Stig
Affiliations: Department of Cardiology, University Hospital, S-22185 Lund | Departments of Internal Medicine, University Hospital, S-22185 Lund | Central Hospital, S-35185 Växjö, Sweden
Abstract: Blood viscosity was measured at different shear rates using a rotational viscometer, and the correlation between blood viscosity and blood haemoglobin concentration was studied. In 10 healthy controls correlation coefficients were: 0,966 at shear rate 40,0 s−1, 0,931 at 19,6 s−1, 0,817 at 2,3 s−1 and 0,816 at 0,8 s−1, p<0,01 to p<0,001. The regression lines for these relationships were then applied to the patient groups to calculate what blood viscosity should be predicted solely from the individual haemoglobin concentration, “predicted blood viscosity”. In 34 patients with cardiovascular diseases (20 patients with coronary artery disease (CAD), 8 patients with idiopathic dilated cardiomyopathy and 6 patients with primary pulmonary hypertension) the correlation between blood viscosity and haemoglobin concentration was less good, for the total patient material 0,748 to 0,613, p<0,001 at all shear rates, and for the CAD patients 0,664 to 0,428, p<0,05 at 3 out of 4 shear rates. Apparently the poorer correlation in the patients was due to a larger influence from factors unrelated to haemoglobin concentration/ haematocrit, as the quotients between individually measured and predicted blood viscosity correlated with measured blood viscosity when the haematocrit factor had been eliminated by in vitro standardisation of sample haematocrits to 45%.
Keywords: Blood viscosity, haemorheology, haemoglobin concentration, microcirculation
DOI: 10.3233/CH-1994-14506
Journal: Clinical Hemorheology and Microcirculation, vol. 14, no. 5, pp. 677-683, 1994
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]