Issue title: Selected Papers from the 28th Congress on Clinical Hemorheology and Microcirculation of the German Society, Munich, Germany, 20–21 November 2009
Article type: Research Article
Authors: Braune, S. | Lange, M. | Richau, K. | Lützow, K. | Weigel, T. | Jung, F.; | Lendlein, A.;
Affiliations: Center for Biomaterial Development, Institute of Polymer Research, GKSS-Forschungszentrum Geesthacht GmbH, Teltow, Germany | Berlin-Brandenburg Center for Regenerative Therapies (BCRT), Berlin, Germany
Note: [] Corresponding author: Prof. A. Lendlein, Center for Biomaterial Development, Institute of Polymer Research, GKSS-Forschungszentrum Geesthacht GmbH, Kanstr. 55, 14513 Teltow, Germany. E-mail: [email protected]
Abstract: The processing of polymers for blood contacting devices can have a major influence on surface properties. In this study, we fabricated poly(ether imide) (PEI) membranes and films to investigate the effects of the processing on physicochemical surface properties by atomic force microscopy (AFM), scanning electron microscopy, contact angle as well as zeta potential measurements. A static platelet adhesion test was performed to analyze the thrombogenicity of both devices. While contact angle measurements showed similar levels of hydrophobicity and zeta potential values were equivalent, mean surface roughness as well as surface energies in the dispersive part were found to be increased for the PEI membrane. The static platelet adhesion test showed a significantly decreased number of adherent platelets per surface area on the PEI film (178.98 ± 102.70/45000 μm2) compared to the PEI membrane (504 ± 314.27/45000μm2) and, consequently, revealed evidence for higher thrombogenicity of the PEI membrane. This study shows that processing can have a significant effect on platelet adhesion to biomaterials, even though, molar weight was identical. Thrombogenicity of polymer-based cardiovascular devices, therefore, have to be evaluated at the final product level, following the entire processing procedure.
DOI: 10.3233/CH-2010-1351
Journal: Clinical Hemorheology and Microcirculation, vol. 46, no. 2-3, pp. 239-250, 2010
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]