Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Zhou, Fengdaoa; b | Wang, Jingyib | Wang, Wenxuanb | Zhou, Haigena; b;
Affiliations: [a] Key Laboratory of Geophysical Exploration Equipment, Ministry Ministry of Education, Jilin University, Changchun, China | [b] College of Instrumentation and Electrical Engineering, Jilin University, Changchun, China
Correspondence: [*] Corresponding author: Haigen Zhou, Key Laboratory of Geophysical Exploration Equipment, Ministry of Education, Jilin University, Changchun, China and College of Instrumentation and Electrical Engineering, Jilin University, Changchun, China. E-mail: [email protected]
Abstract: In the ground-airborne frequency domain electromagnetic detection, the receving system converts the magnetic field signal into an electrical signal representing the magnetic field signal. In order to accurately obtain the relationship between the magnetic field signal and the electrical signal, it is necessary to avoid the influence of environment and other factors on the system accuracy through on-site calibration. This requires high calibration accuracy, simple operation, portable equipment and strong adaptability to the environment. However, the existing calibration methods put forward higher requirements for instruments and environment. For example, the calibration of uniform magnetic field generated by Helmholtz coil needs to shield external magnetic field interference. In this paper, an overall calibration method of measurement system based on magnetic source excitation is proposed to meet the requirements of electromagnetic field accurate measurement in ground-airborne frequency domain. Firstly, based on the electromagnetic measurement method in ground-airborne frequency domain, the overall calibration method and principle of the detection system are introduced. Then, based on the computable standard magnetic field generated by the magnetic source transmitting coil, determine the measured voltage obtained by the receiving system, get the calibration coefficient of the receiving system. At last,the source of standard uncertainty related to calibration is analyzed, and the uncertainty is evaluated. In addition, the method is verified by comparing the calibration results with those obtained by Braunbeck coil calibration.
Keywords: Ground-air frequency domain electromagnetic detection, air-core sensor (ACS), magnetic source excitation, calibration
DOI: 10.3233/JAE-220197
Journal: International Journal of Applied Electromagnetics and Mechanics, vol. 72, no. 4, pp. 343-360, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]