Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Yang, Maoa; b | Zhang, Honga; | Zhou, Jiantinga | Jiang, Hejinga | Zheng, Yua | Qiu, Jiana
Affiliations: [a] School of Civil Engineering, Chongqing Jiaotong University, Chongqing, China | [b] School of Civil Engineering, Chongqing Three Gorges College, Chongqing, China
Correspondence: [*] Corresponding author: Hong Zhang, School of Civil Engineering, Chongqing Jiaotong University, Chongqing 400074, China. E-mail: [email protected]
Abstract: Both corrosion defects and stress can cause magnetic field mutations, so the effect of stress must be considered in the magnetic detection of steel corrosion. This paper focuses on exploring the influence law of tension on magnetic signals of the corroded specimens. Based on the spontaneous magnetic leakage mechanism of steel bar corrosion and the stress magnetization model, the magnetic memory detection of corroded reinforced concrete under tension was carried out. The magnetic characteristics of corroded specimens before and after loading were analyzed. The corrosion positions of the specimens can be determined according to the representative mutation points (RMP) of the Byc(0) curves, and the magnetic index I2 was proposed to roughly determine the corrosion degree of the specimens when the specimens were not subjected to tensions. The experimental results showed that the RMP of Byc(F) curves can still represent corrosion positions when the specimens were under tension. The theoretical derivation showed that the magnetic field change caused by tensile force is limited, and the maximum value of the magnetic field change caused by tensile force can be obtained. Based on this, the corresponding I3-F curves were obtained through the test. The magnetic field change caused by the most unfavorable tensions was calculated to analyze its influence on corrosion magnetic detection. Compared with I2, the relationship between I3 and the corrosion degree was more discrete, indicating that tensile forces affected the quantitative detection of corrosion. Still, the magnetic field caused by corrosion played a leading role. The verification showed that the measured corrosion positions of reinforced concrete specimens were in good agreement with those detected by the magnetic memory method.
Keywords: Corrosion, reinforced concrete, magnetic memory detection, tensile load, influence law
DOI: 10.3233/JAE-210172
Journal: International Journal of Applied Electromagnetics and Mechanics, vol. 68, no. 4, pp. 483-499, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]