Abstract: With the rapid development of UHV power transmission and transformation project in our country, the gradually increasing electromagnetic capacity and electromagnetic loads of power transformers causes serious heating of the transformers. Therefore, it is particularly important to accurately calculate its temperature rise. Based on field-circuit coupling method, this paper took a 240000 KVA, 330 KV power transformer as the research object to calculate the whole temperature rise and heat transfer characteristics. Firstly, the average velocity of fluid was gotten by three-dimensional flow field of transformer which is calculated by establishing thermal network model of the transformer, phase winding and related structures. And then substitute it into thermal network model. The whole average temperature and temperature rise was gotten by using first law of thermodinamics and after the iteration. And according to the temperature rise test, this paper comprised and analyzed the computed results of thermal network and numerical analysis. Results showed that the error of the thermal network model was within the scope of the permit, and it was simple and quick. The method can provide basis for the future heat transfer research and temperature rise prediction of transformer.
Keywords: Oil-immersed transformer, field-circuit coupling, thermal networks, temperature rise prediction
DOI: 10.3233/JAE-210157
Journal: International Journal of Applied Electromagnetics and Mechanics, vol. 70, no. 1, pp. 55-72, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]