Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: He, Yuchenga | He, Weia | Xiong, Bingquana | Guo, Panb | Xu, Zhenga;
Affiliations: [a] State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing 400044, China | [b] School of Physics and Electronic Engineering, Chongqing Normal University, Chongqing 401331, China
Correspondence: [*] Corresponding author: Z. Xu, State Key Laboratory of Power Transmission Equipment and System Security and NewTechnology, Chongqing University, Chongqing 400044, China. Tel./Fax: +86 13527475882; E-mail: [email protected]
Abstract: Ultra-low field magnetic resonance imaging (MRI) is a popular research topic in the field of mobile medical imaging. We construct a 50 mT ultra-low field MRI system for real-time monitoring of intracranial bleeding. The region of interest is a spherical space with a diameter of 200 mm, which is sufficiently large for a brain tissue. The homogeneity of the magnetic field determines the signal-to-noise ratio of MRI directly. First, the distribution of the main magnetic field is measured and expanded by using orthogonal spherical harmonic functions. Second, a harmonic coefficient method is used to design active shim coils of the first two orders, with each coil generating a specific harmonic magnetic field. Lastly, the contour distribution of the stream function is utilized to obtain the winding of the shim coils. Results show that each shim coil can generate a pure harmonic magnetic field within an error of 5%. The magnetic field uniformity is reduced from 137 ppm to 28 ppm by these shim coils.
Keywords: Active shim coils, magnetic resonance imaging, ultra-low field
DOI: 10.3233/JAE-180025
Journal: International Journal of Applied Electromagnetics and Mechanics, vol. 58, no. 3, pp. 359-370, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]