Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Wang, Shuaibinga; * | Li, Lina | Xie, Yuqinga | Zhao, Guoliangb
Affiliations: [a] State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China | [b] Global Energy Interconnection Research Institute, Beijing, China
Correspondence: [*] Corresponding author: Shuaibing Wang, State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China. Tel.: +86 15810237653; E-mail:[email protected]
Abstract: The operation conditions of series transformer in Unified Power Flow Controller (UPFC) system are analyzed, and a shell-type structural scheme is proposed in this paper. Taking into account the nonlinear characteristic and the eddy current effect of the ferromagnetic materials, the effective complex permeability is adopted to calculate the nonlinear reluctance of the core, and an electromagnetic transient model of the series transformer is presented based on the duality theory of electric circuit and magnetic circuit, which is one key part of the comprehensive simulation model of UPFC. Besides, the improved magnetic circuit method is coupled with the electric circuit to analyze the special three-phase asymmetrical DC bias phenomenon of series transformer. Some experiments about no-load switching and asymmetrical DC bias on a low-voltage series transformer prototype have been done to verify the transient model and the improved magnetic circuit method, respectively. Finally, the reactive power of the no-load series transformer prototype under asymmetrical DC bias is calculated, the results indicate that the variation of the reactive power of series transformer under asymmetrical DC bias becomes more complicated, which increases the difficulty of voltage regulation in UPFC system.
Keywords: Series transformer, duality theory, complex permeability, asymmetrical DC bias, reactive power
DOI: 10.3233/JAE-160064
Journal: International Journal of Applied Electromagnetics and Mechanics, vol. 53, no. 3, pp. 469-485, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]