Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Subtitle:
Article type: Research Article
Authors: Zhang, Chao | Qiu, Jinhao* | Ji, Hongli | Shan, Shengbo | Zhao, Jinling
Affiliations: State Key Laboratory of Mechanics and Control of Mechanical Structures, Nanjing University of Aeronautics {&} Astronautics, Nanjing, China
Correspondence: [*] Corresponding author: Jinhao Qiu, State Key Laboratory of Mechanics and Control of Mechanical Structures, Nanjing University of Aeronautics & Astronautics, Nanjing, China. Tel.: +86 25 84891123; E-mail:[email protected]
Abstract: A spatially distributed array of piezoelectric sensors is widely used in structural health monitoring (SHM) for active ultrasonic methods. Owing to many advantages of delay-and-sum algorithm such as intuition, low computation cost and accurate imaging result, it is very suitable for damage localization. However, due to the dispersion effect of Lamb waves, the wave packet becomes wide and distorted as it propagates in the structure which will have a negative effect in the spatial resolution of the damage imaging. This paper presents an active imaging method using warped frequency transform (WFT) to improve the spatial resolution of the imaging result. In WFT, the warped frequency range is limited in narrowband and the central frequency is fixed to keep the wave packet undistorted. Then, the dispersion effect can be compensated and the velocity of the wave packet is converted into phase velocity which is much lower than group velocity. Due to the compensated wave packet and low wave velocity, the spatial resolution of the delay-and-sum algorithm is improved. Both single damage and dual adjacent damages are detected in the experiments. The comparisons between delay-and-sum algorithm with and without WFT are made to demonstrate the proposed method.
Keywords: Lamb wave, damage localization, warped frequency transform, active structural health monitoring
DOI: 10.3233/JAE-140072
Journal: International Journal of Applied Electromagnetics and Mechanics, vol. 47, no. 4, pp. 897-909, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]