Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Yang, Fana; * | Guo, Xingyea | Liu, Xinghuab | Dai, Fenga | Fan, Lingqianga | He, Weia
Affiliations: [a] State Key Laboratory of Transmission and Distribution Equipment and System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing, China | [b] Shandong Zibo Power Supply Bureau, Zibo, Shandong, China
Correspondence: [*] Corresponding author: Fan Yang, State Key Laboratory of Transmission and Distribution Equipment and System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing 400030, China. Tel.: +86 1399 6289 198; E-mail: [email protected]
Abstract: The electromagnetic transient can be used to analyze the stability of power systems. In the paper, the electromagnetic transient of an AC-DC interconnected system under different faults is investigated, and interaction between the AC system and DC system is analyzed. Firstly electromagnetic transient models for the components in a high voltage direct current (HVDC) transmission system are presented, including model for converter transformer, harmonic filters, transmission line and control system. Then simulation based on electromagnetic transient model for a ± 800 kV bipolar HVDC-AC interconnected system is carried out, and both the steady state and step response performance are checked to verify the accuracy of the model. Finally electromagnetic transient of the system under different faults is investigated, including different grounding faults on AC side, fault on DC side and fault of filters. Transient responses are analyzed, including the recovering time from oscillation caused by faults and possibility of commutation failure (CF).
Keywords: Electromagnetic transient, HVDC interconnected system, CF, short-circuit fault, open-circuit fault
DOI: 10.3233/JAE-131737
Journal: International Journal of Applied Electromagnetics and Mechanics, vol. 44, no. 1, pp. 69-86, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]