The aim of the International Journal of Applied Electromagnetics and Mechanics is to contribute to intersciences coupling applied electromagnetics, mechanics and materials. The journal also intends to stimulate the further development of current technology in industry. The main subjects covered by the journal are:
- Physics and mechanics of electromagnetic materials and devices
- Computational electromagnetic in materials and devices
- Applications of electromagnetic fields and forces
The three interrelated key subjects - materials, electromagnetics and mechanics - include the following aspects: control, micromachines, intelligent structure, inverse problem, eddy current analysis, electromagnetic NDE, magnetic materials, magnetoelastic effects in materials, bioelectromagnetics, magnetosolid mechanics, magnetic levitations, applied physics of superconductors, superconducting magnet technology, superconducting propulsion system, nuclear fusion reactor components and wave propagation in electromagnetic fields.
Authors: Zhang, Wenguang | Tang, Jiaqi | Yin, Xuele
Article Type: Research Article
Abstract: A novel neural electrode based on small-deflection theory to reduce the tissue injury caused by micromotion was designed to improve the lifetime of neural electrode. The results of the finite element analysis revealed that the novel neural electrode showed excellent micromotion-attenuation capability. And designing a reasonable size of opening area can effectively improve neural electrode-brain tissue interface mechanical states. The novel electrode is inferred to prolong the lifetime of neural electrodes.
Keywords: Neural electrode, small-deflection theory, finite element method (FEM), micromotion
DOI: 10.3233/JAE-171058
Citation: International Journal of Applied Electromagnetics and Mechanics, vol. 59, no. 3, pp. 1065-1071, 2019
Authors: Zhang, Wenguang | Tang, Jiaqi | Li, Zhengwei
Article Type: Research Article
Abstract: In order to reveal the effects of insertion speed with hydrogel coatings on tissue injury, comparative experiments were carried out with the naked neural probes (as the reference) and probes with PVA-H coatings based on tissue injury evaluation system. It was found that the coatings of the neural probes would cause more serious tissue injury during the insertion process. And the insertion speed could alleviate the negative effects on the tissue injury caused by implantation of neural probes.
Keywords: Neural probe, tissue injury, PVA-H coatings, insertion speed
DOI: 10.3233/JAE-171104
Citation: International Journal of Applied Electromagnetics and Mechanics, vol. 59, no. 3, pp. 1073-1079, 2019
Authors: Zhang, Feng | Jiang, Changqing | Mo, Xiaolong | Liu, Yinghua | Xie, Huimin | Li, Luming
Article Type: Research Article
Abstract: Deep brain stimulation (DBS) is an effective therapy for treating neurological disorders, while magnetic resonance imaging (MRI) is a valuable method for clinical diagnosis and research. However, DBS systems in clinical MRI are under the influence of displacement force, torque and device vibration, which may be hazardous to patients after DBS implantation surgery. In this study, we evaluated these hazardous effects under 3T MRI. A set of apparatus were designed and built and the corresponding methods for safety assessment were also proposed. Results showed that the displacement force, torque and vibration of the DBS system under 3T MRI were safe. …Furthermore, this study demonstrates an example of an MRI compatibility test that can be applied to many other medical instruments. Show more
Keywords: Deep brain stimulation, magnetic resonance imaging, force, torque, vibration
DOI: 10.3233/JAE-171084
Citation: International Journal of Applied Electromagnetics and Mechanics, vol. 59, no. 3, pp. 1081-1086, 2019
Authors: Xia, Yu | Feng, Chendong | Xiong, Yinze | Luo, Yun | Li, Xiang
Article Type: Research Article
Abstract: Additive manufacturing technology has been widely used for the fabrication of porous titanium (Ti) orthopedic implants. Though high porosities and low stiffness of the scaffolds are benefit for bone ingrowth, the compressive strength and fatigue performance of the scaffolds are still necessary for load-bearing applications. In this study, a novel porous scaffold with framework structure was designed and fabricated using selective laser melting process. The mechanical properties of the porous Ti scaffolds were evaluated. The results showed that the compressive strength of the scaffolds possessing framework structure was enhanced significantly with the porosity decreased slightly. In addition to static mechanical …properties, the fatigue properties of the porous Ti scaffolds were also improved via the framework structure. Show more
Keywords: Additive manufacturing, porous titanium, compressive strength, fatigue test, framework structure
DOI: 10.3233/JAE-171197
Citation: International Journal of Applied Electromagnetics and Mechanics, vol. 59, no. 3, pp. 1087-1095, 2019
Authors: Xiong, Yinze | Gao, Ruining | Zhang, Hang | Li, Xiang
Article Type: Research Article
Abstract: A novel titanium (Ti) dental implant with pore architecture and enhanced structure was designed and fabricated using selective laser melting (SLM). Aimed at adding micro/nano structures on the porous Ti implant, alkali heat treatment was proposed. The fully interconnected porous part was in the midsection of the implant. The reinforced strut was embedded in the center of the porous part. The mechanical properties and surface morphology of the porous Ti implant were characterized. The desired micro/nano surface was obtained after alkali heat treatment. Mechanical test results showed that the ultimate strength was about 715 MPa, enough to withstand normal occlusal force …and the stiffness of the Ti dental implant was about 26 GPa. This novel porous titanium dental implant with micro/nano surface may be promising to repair missing teeth. Show more
Keywords: Dental implant, surface modification, porous titanium
DOI: 10.3233/JAE-171166
Citation: International Journal of Applied Electromagnetics and Mechanics, vol. 59, no. 3, pp. 1097-1102, 2019
Authors: Kang, Semin | Okuyama, Takeshi | Tanaka, Mami
Article Type: Research Article
Abstract: This study aims to elucidate the effect of surface roughness on feeling of stiffness. In order to clarify the effect of surface roughness, we focus on the fingertip motion during the sensory evaluation of stiffness feeling. In this paper, the pair comparison method was used in sensory evaluation with two kinds of instruction. One is that subjects evaluated stiffness of samples freely. The other is that subjects evaluated them with feeling the surface roughness. During the sensory evaluation, subject’s fingertip trajectories and contact force with the samples were measured. From the results of sensory evaluation, it was found that surface …roughness obviously affected feeling of stiffness in the case of instruction that subjects evaluated them with feeling the surface roughness. Show more
Keywords: Tactile sensation, stiffness, roughness, sensory evaluation, pair comparison method
DOI: 10.3233/JAE-171028
Citation: International Journal of Applied Electromagnetics and Mechanics, vol. 59, no. 3, pp. 1103-1110, 2019
Authors: Watanabe, Keisuke | Abe, Takao | Isozaki, Goushiro | Okuyama, Takeshi | Tanaka, Mami
Article Type: Research Article
Abstract: Monitoring of scratching motion accompanied with itch is important for the medical treatment of skin diseases. Although there were some studies on monitoring scratching motion, the mechanical characteristics of scratching have not been researched enough. Therefore, in this paper, we developed an estimation method of human scratching motion characteristics, especially contact force. In experiment, we measured motions of scratching weakly and strongly against artificial skin placed on three-axis force sensor. Displacement of artificial skin and fingertip trajectory were analyzed by using three-dimensional motion measurement system and compared with contact force measured by the force sensor. In addition, an analysis of …scratching motion against human skin by using the developed system was conducted too. From these results, we confirmed that measuring skin displacement of skin surface and fingertip trajectory are effective for the estimation of the mechanical characteristics of scratching. Show more
Keywords: Scratching, motion analysis, itch, skin damage, artificial skin
DOI: 10.3233/JAE-171181
Citation: International Journal of Applied Electromagnetics and Mechanics, vol. 59, no. 3, pp. 1111-1118, 2019
Authors: Okuyama, Takeshi | Kobayashi, Kouhei | Tanaka, Mami
Article Type: Research Article
Abstract: In this paper, a novel wearable sensor to estimate the force applied at fingertip is developed. To perform rehabilitation of fingers effectively, it is important to measure finger force of patients without inhibiting grip sensation. Therefore, we focused on the relationship between tension of tendon and fingertip force, and proposed a ring type sensor to estimate the fingertip force from tension of tendon. First, the ring type sensor is fabricated. And we investigate the relationship between sensor output and fingertip force by experiments. From the results, it was found that the sensor output is related to the fingertip force. And …we obtained a relational expression to calculate fingertip force from sensor output. Next, estimation experiment of fingertip force was conducted. It was confirmed that the developed sensor system is available to estimate the fingertip force without placing the sensor on the fingertip. Show more
Keywords: Fingertip force, tendon, tension, wearable sensor
DOI: 10.3233/JAE-171143
Citation: International Journal of Applied Electromagnetics and Mechanics, vol. 59, no. 3, pp. 1119-1126, 2019
Authors: Saito, Sho | Okuyama, Takeshi | Tanaka, Mami
Article Type: Research Article
Abstract: Elucidating causes of infertility is important to conduct proper treatment for infertility. Mechanical characteristics of the endometrium may be mentioned as a cause of infertility. In this paper, we focus on softness of the endometrium. As a fundamental research for the softness measurement of the endometrium, we developed a system for measuring softness of cylindrical objects by using a balloon catheter. The measurement system is composed of a balloon catheter, a syringe and a pressure sensor. Young’s modulus of cylindrical objects is calculated from balloon radius and internal pressure when the balloon is expanded in the object. In the experiment, …we prepared four kinds of cylindrical samples with different softness. By using the measurement system, Young’s modulus of each cylindrical sample is estimated. And the estimated values are compared with Young’s modulus measured by compression test. From the results, it was found that the developed system is effective for measuring softness of cylindrical objects. Show more
Keywords: Balloon catheter, young’s modulus, measurement, softness
DOI: 10.3233/JAE-171135
Citation: International Journal of Applied Electromagnetics and Mechanics, vol. 59, no. 3, pp. 1127-1134, 2019
Authors: Wang, Minghui | Yu, Hongliu
Article Type: Research Article
Abstract: Fecal incontinence caused by sphincter dysfunction is a difficult medical problem which has not been fully resolved. An artificial anal sphincter (AAS) is considered an eventual choice as prosthesis to maintain anal continence. Currently, Acticon Neosphincter, the only device certified by the US Food and Drug Administration can not maintain the long-term effectiveness. The crucial problem of this study was to keeping long-term biomechanical compatibility between the AAS and the surrounding tissue. This paper presented a design of an AAS with constant force or pressure using superelastic shape memory alloy (SMA) to solve the problem. A C-shaped superelastic SMA sheet …was optimized to obtain constant force or pressure by combing finite element analysis with ANSYS and genetic algorithm in MATLAB. The result of optimization was validated by performing an experiment. The optimized model was embedding into the device to realize clamping the soft tissue with constant force, which was confirmed by experiments. Show more
Keywords: Artificial anal sphincter, constant force, superelasticity
DOI: 10.3233/JAE-171065
Citation: International Journal of Applied Electromagnetics and Mechanics, vol. 59, no. 3, pp. 1135-1141, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]