Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Proceedings from the 17th International Symposium on Applied Electromagnetics and Mechanics (ISEM 2015)
Guest editors: Fumio Kojima, Futoshi Kobayashi and Hiroyuki Nakamoto
Article type: Research Article
Authors: Zhu, Liangfan | Wu, Yue | Luo, Yun*
Affiliations: State Key Laboratory of Mechanical System and Vibration, Institute of Biomedical Manufacturing and Life Quality Engineering, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
Correspondence: [*] Corresponding author: Yun Luo, State Key Laboratory of Mechanical System and Vibration, Institute of Biomedical Manufacturing and Life Quality Engineering, School of Mechanical Engineering, Shanghai Jiao Tong University, 800 Dong Chuan Rd., Shanghai 200240, China. Tel./Fax: +21 3420 6078; E-mail:[email protected]
Abstract: Left ventricular assist devices (LVADs) have been verified as an effective way for the patients who suffer from the end-stage heart failure. In order to prolong the lifespan of the LVAD, a blood pump with magnetically or hydrodynamically suspended impeller is preferred. Magnetic bearings need active control consuming extra energy and hydrodynamic bearings running at very small clearance gaps can yield increased blood damage. A novel blood pump with a passively injection suspended impeller and a gap between casing and impeller in the large range of 0.6 mm is presented in this paper. This design allows the blood pump to eliminate the sensors for active control and operate at low levels of shearing stress. The computational fluid dynamics (CFD) analysis was conducted to primary verify the effectiveness of injection principle. The hydraulic performance and axial levitation performance test were performed to prove feasibility of the design.
Keywords: Left ventricular assist device, injection suspended impeller, hydrodynamic force
DOI: 10.3233/JAE-162159
Journal: International Journal of Applied Electromagnetics and Mechanics, vol. 52, no. 1-2, pp. 525-530, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]