Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Shi, Wenzea; b | Wu, Yunxina; b; c; * | Gong, Haia; b; c | Zhang, Taoa; b | Tan, Liangchena; b | Han, Leia; b
Affiliations: [a] State Key Laboratory of High Performance Complex Manufacturing, Central South University, Changsha 410083, Hunan, China | [b] School of Mechanical and Electrical Engineering, Central South University, Changsha 410083, Hunan, China | [c] Nonferrous Metal Oriented Advanced Structural Materials and Manufacturing Cooperative Innovation Center, Changsha 410083, Hunan, China
Correspondence: [*] Corresponding author: Yunxin Wu, School of Electrical and Mechanical Engineering, Central South University, Changsha 410083, Hunan, China. Tel.: +86 731 8866 0476; E-mail: [email protected].
Abstract: The application of Electromagnetic Acoustic Transducers (EMATs) into metal materials has been hard to implement for the technical problems of low transduction efficiency and high sensitivity of lift-off variation. The process of transmission and detection of a shear wave in a spiral coil EMAT is established based on a 2-D axisymmetric model using finite element method. A new equivalent reception circuit for an EMAT receiver is provided, and it takes the open-circuit voltage of a receiving coil, the coil equivalent impedance, impedance matching network, and the input impedance of a preamplifier into consideration. On this basis, the conversion efficiency and lift-off performance of the EMAT transmitter and receiver are investigated with respect to coil equivalent impedance, coil conductor diameter, impedance matching parameters, plate-to-coil distance and backplate thickness. Results indicate that compared with the specified EMAT without a backplate at a lift-off of 2 mm, the conversion efficiency and lift-off performance of the transmitting EMAT with a plate-to-coil distance of 1.5 mm can be respectively improved by 103.5% and 2.4 dB/mm, and the conversion efficiency and lift-off performance of the receiving EMAT with a plate-to-coil distance of 1.5 mm can be respectively enhanced by 85.5% and 1.6 dB/mm.
Keywords: Spiral coil EMAT, transmitter and receiver, lift-off performance, conversion efficiency, equivalent reception circuit
DOI: 10.3233/JAE-170027
Journal: International Journal of Applied Electromagnetics and Mechanics, vol. 56, no. 2, pp. 173-194, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]