Issue title: 2th European Conference on Post Marketing Surveillance for Medical Implants
Article type: Research Article
Authors: Buma, Pieter
Affiliations: Department of Orthopaedics, Section Histomorphology, University Hospital Nijmegen, P.O. Box 9101, 6500 HB Nijmegen, The Netherlands, Tel: +31 243 614932; Fax: +31 243 540230
Abstract: For the evaluation of newly developed orthopaedic implantations, it is of utmost importance to collect all available information with respect to the behaviour of the implant. Retrieval analysis of well-functioning implants (post-mortem) and of failures (during revision) may give very valuable information with respect to short term reactions of the organism to the implant. In this case, bone reactions were studied around a titanium, hydroxyapatite (HA) coated Osteonics bipolar hip prosthesis, which was revised for severe mid thigh pain four years after implantation. Scarce remnants of a coating-like material on the surface of the prosthesis were found after inspection of the retrieved prosthesis using a dissecting microscope. Histology of these remnants and of the bony side of the bone-HA interface, failed to reveal any remnants of a HA coating. Trabecular bone which closely followed the contour of the prosthesis was found at the bone-prosthesis interface. Facing the prosthesis, this trabecular bone was mainly immature callous bone. At other locations, where mineralized bone faced the prosthesis, many small dark titanium wear particles were found. Similar particles were found in macrophages in the intertrabecular medullary space. Polyethylene wear particles were specifically located in macrophages in a soft tissue interface at more distal levels along the stem of the prosthesis. Although the observations presented in this case cannot be generalized, it clearly shows that the HA coating layer had completely disappeared after four years. More detailed retrieval studies and longer clinical follow-up studies are needed before a final evaluation of the behaviour of HA coatings and long term fixation of HA-coated prostheses can be made.
DOI: 10.3233/JRS-1996-8120
Journal: International Journal of Risk and Safety in Medicine, vol. 8, no. 1, pp. 111-117, 1996
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]