Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Schier, Roberta | Marks, James D.b; *
Affiliations: [a] Departments of Anesthesia and Pharmaceutical Chemistry, University of California, San Francisco | [b] Department of Anesthesia, San Francisco General Hospital, San Francisco, CA 94110, USA
Correspondence: [*] Correspondence and reprint requests to James D. Marks, Department of Anesthesia, Rm 3C-38, San Francisco General Hospital, 1001 Potrero, San Francisco, CA 94110, USA.
Abstract: Selection of higher affinity mutant phage antibodies has proven less than straightforward due to sequence dependent differences in phage antibody expression, toxicity to Escherichia coli, and difficulty in eluting the highest affinity phage. These differences lead to selection for increased levels of expression or decreased toxicity rather than for higher affinity. In this work, we demonstrate how surface plasmon resonance as employed in the BIAcore can be used to increase the efficiency of phage antibody selections, yielding greater increments in affinity from a single library. A mutant phage antibody library was created by randomizing nine amino acids located in the VL CDR3 of C6.5, a human scFv which binds the tumor antigen c-erbB-2 with a Kd of 1.6 × 10−8 M. The library was subjected to five rounds of selection in solution using decreasing concentrations of biotinylated c-erbB-2. After each round of selection, polyclonal phage were prepared and the rate of binding to c-erbB-2 determined in a BIAcore under mass transport limited conditions. Determination of the rate of binding permitted calculation of the concentration, and hence percent, of binding phage present. Results were used to select the antigen concentration for the next round of selection. To determine the optimal eluent, polyclonal phage was injected in a BIAcore and eluted using one of five different solutions (10 mM HCl, 50 mM HCl, 100 mM HCl, 100 mM triethylamine, 2.6 M MgCl2). Differences were observed in eluent efficacy, which was reflected in significant differences in the affinities of phage antibodies isolated from the library after a round of selection using the different eluents. Use of the BIAcore to determine the optimal eluent and guide the antigen concentration used for selection yielded a C6.5 mutant with a 16 fold reduction in Kd (Kd = 1.0 × 10−9 M). This represents at least a twofold greater increment in affinity than previously obtained from a single library of phage antibodies which bind antigens.
Keywords: Phage display, antibody fragment, affinity maturation, surface plasmon resonance, BIAcore, c-erbB-2
DOI: 10.3233/HAB-1996-7302
Journal: Human Antibodies, vol. 7, no. 3, pp. 97-105, 1996
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]