Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Purchase individual online access for 1 year to this journal.
Price: EUR 160.00Authors: Huang, Deyang | Miao, Hengyuan | Zhang, Ziqi | Yang, Yanhong | Zhang, Lieguang | Lure, Fleming Y.M. | Wang, Zixian | Jaeger, Stefan | Guo, Lin | Xu, Tao | Liu, Jinxin
Article Type: Research Article
Abstract: BACKGROUND AND OBJECTIVE: Monitoring recovery process of coronavirus disease 2019 (COVID-19) patients released from hospital is crucial for exploring residual effects of COVID-19 and beneficial for clinical care. In this study, a comprehensive analysis was carried out to clarify residual effects of COVID-19 on hospital discharged patients. METHODS: Two hundred sixty-eight cases with laboratory measured data at hospital discharge record and five follow-up visits were retrospectively collected to carry out statistical data analysis comprehensively, which includes multiple statistical methods (e.g., chi-square, T-test and regression) used in this study. RESULTS: Study found that 13 of 21 hematologic …parameters in laboratory measured dataset and volume ratio of right lung lesions on CT images highly associated with COVID-19. Moderate patients had statistically significant lower neutrophils than mild and severe patients after hospital discharge, which is probably caused by more efforts on severe patients and slightly neglection of moderate patients. COVID-19 has residual effects on neutrophil-to-lymphocyte ratio (NLR) of patients who have hypertension or chronic obstructive pulmonary disease (COPD). After released from hospital, female showed better performance in T lymphocytes subset cells, especially T helper lymphocyte% (16% higher than male). According to this sex-based differentiation of COVID-19, male should be recommended to take clinical test more frequently to monitor recovery of immune system. Patients over 60 years old showed unstable recovery process of immune cells (e.g., CD45 + lymphocyte) within 75 days after discharge requiring longer clinical care. Additionally, right lung was vulnerable to COVID-19 and required more time to recover than left lung. CONCLUSIONS: Criterion of hospital discharge and strategy of clinical care should be flexible in different cases due to residual effects of COVID-19, which depend on several impact factors. Revealing remaining effects of COVID-19 is an effective way to eliminate disorder of mental health caused by COVID-19 infection. Show more
Keywords: COVID-19 pneumonia, hospital discharge, dynamic changes analysis, computed tomography (CT) lung image, routine blood test parameters
DOI: 10.3233/XST-210920
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 5, pp. 741-762, 2021
Authors: Mao, Ning | Jiao, Zimei | Duan, Shaofeng | Xu, Cong | Xie, Haizhu
Article Type: Research Article
Abstract: OBJECTIVE: To develop and validate a radiomics model based on contrast-enhanced spectral mammography (CESM), and preoperatively discriminate low-grade (grade I/II) and high-grade (grade III) invasive breast cancer. METHOD: A total of 205 patients with CESM examination and pathologically confirmed invasive breast cancer were retrospectively enrolled. We randomly divided patients into two independent sets namely, training set (164 patients) and test set (41 patients) with a ratio of 8:2. Radiomics features were extracted from the low-energy and subtracted images. The least absolute shrinkage and selection operator (LASSO) logistic regression were established for feature selection, which were then utilized to …construct three classification models namely, low energy, subtracted images and their combined model to discriminate high- and low-grade invasive breast cancer. Receiver operator characteristic (ROC) curves were used to confirm performance of three models in training set. The clinical usefulness was evaluated by using decision curve analysis (DCA). An independent test set was used to confirm the discriminatory power of the models. To test robustness of the result, we used 100 times LGOCV (leave group out cross validation) to validate three models. RESULTS: From initial radiomics feature pool, 17 and 11 features were selected for low-energy image and subtracted image, respectively. The combined model using 28 features showed the best performance for preoperatively evaluating the histologic grade of invasive breast cancer, with an area under the curve, AUC = 0.88, and 95%confidence interval [CI] 0.85 to 0.92 in the training set and AUC = 0.80 (95%CI 0.67 to 0.92) in the test set. The mean AUC of LGOCV is 0.82. CONCLUSIONS: CESM-based radiomics model is a non-invasive predictive tool that demonstrates good application prospects in preoperatively predicting histological grade of invasive breast cancer. Show more
Keywords: Breast cancer, histologic grade, contrast-enhanced spectral mammography, radiomics, preoperative prediction
DOI: 10.3233/XST-210886
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 5, pp. 763-772, 2021
Authors: Romero, Ignacio O. | Li, Changqing
Article Type: Research Article
Abstract: BACKGROUND: Pencil beam X-ray luminescence computed tomography (XLCT) imaging provides superior spatial resolution than other imaging geometries like sheet beam and cone beam geometries. However, the pencil beam geometry suffers from long scan times, resulting in concerns overdose which discourages the use of pencil beam XLCT. OBJECTIVE: The dose deposited in pencil beam XLCT imaging was investigated to estimate the dose from one angular projection scan with three different X-ray sources. The dose deposited in a typical small animal XLCT imaging was investigated. METHODS: A Monte Carlo simulation platform, GATE (Geant4 Application for Tomographic Emission) was …used to estimate the dose from one angular projection scan of a mouse leg model with three different X-ray sources. Dose estimations from a six angular projection scan by three different X-ray source energies were performed in GATE on a mouse trunk model composed of muscle, spine bone, and a tumor. RESULTS: With the Sigray source, the bone marrow of mouse leg was estimated to have a radiation dose of 44 mGy for a typical XLCT imaging with six angular projections, a scan step size of 100 micrometers, and 106 X-ray photons per linear scan. With the Sigray X-ray source and the typical XLCT scanning parameters, we estimated the dose of spine bone, muscle tissues, and tumor structures of the mouse trunk were 38.49 mGy, 15.07 mGy, and 16.87 mGy, respectively. CONCLUSION: Our results indicate that an X-ray benchtop source (like the X-ray source from Sigray Inc.) with high brilliance and quasi-monochromatic properties can reduce dose concerns with the pencil beam geometry. Findings of this work can be applicable to other imaging modalities like X-ray fluorescence computed tomography if the imaging protocol consists of the pencil beam geometry. Show more
Keywords: X-ray luminescence computed tomography (XLCT), X-ray imaging, radiation dose, Geant4 application for tomographic emission (GATE), Geant4
DOI: 10.3233/XST-210904
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 5, pp. 773-784, 2021
Authors: Nijiati, Mayidili | Zhang, Ziqi | Abulizi, Abudoukeyoumujiang | Miao, Hengyuan | Tuluhong, Aikebaierjiang | Quan, Shenwen | Guo, Lin | Xu, Tao | Zou, Xiaoguang
Article Type: Research Article
Abstract: Tuberculosis (TB) is a major health issue with high mortality rates worldwide. Recently, tremendous researches of artificial intelligence (AI) have been conducted targeting at TB to reduce the diagnostic burden. However, most researches are conducted in the developed urban areas. The feasibility of applying AI in low-resource settings remains unexplored. In this study, we apply an automated detection (AI) system to screen a large population in an underdeveloped area and evaluate feasibility and contribution of applying AI to help local radiologists detect and diagnose TB using chest X-ray (CXR) images. First, we divide image data into one training dataset including …2627 TB-positive cases and 7375 TB-negative cases and one testing dataset containing 276 TB-positive cases and 619 TB-negative cases, respectively. Next, in building AI system, the experiment includes image labeling and preprocessing, model training and testing. A segmentation model named TB-UNet is also built to detect diseased regions, which uses ResNeXt as the encoder of U-Net. We use AI-generated confidence score to predict the likelihood of each testing case being TB-positive. Then, we conduct two experiments to compare results between the AI system and radiologists with and without AI assistance. Study results show that AI system yields TB detection accuracy of 85%, which is much higher than detection accuracy of radiologists (62%) without AI assistance. In addition, with AI assistance, the TB diagnostic sensitivity of local radiologists is improved by 11.8%. Therefore, this study demonstrates that AI has great potential to help detection, prevention, and control of TB in low-resource settings, particularly in areas with more scant doctors and higher rates of the infected population. Show more
Keywords: Artificial intelligence (AI), tuberculosis (TB) diagnosis, low-resource settings, radiologists, chest X-rays (CXRs), assistance, convolutional neural network
DOI: 10.3233/XST-210894
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 5, pp. 785-796, 2021
Authors: Huang, Ying | Wan, Qian | Chen, Zixiang | Hu, Zhanli | Cheng, Guanxun | Qi, Yulong
Article Type: Research Article
Abstract: Reducing X-ray radiation is beneficial for reducing the risk of cancer in patients. There are two main approaches for achieving this goal namely, one is to reduce the X-ray current, and another is to apply sparse-view protocols to do image scanning and projections. However, these techniques usually lead to degradation of the reconstructed image quality, resulting in excessive noise and severe edge artifacts, which seriously affect the diagnosis result. In order to overcome such limitation, this study proposes and tests an algorithm based on guided kernel filtering. The algorithm combines the characteristics of anisotropic edges between adjacent image voxels, expresses …the relevant weights with an exponential function, and adjusts the weights adaptively through local gray gradients to better preserve the image structure while suppressing noise information. Experiments show that the proposed method can effectively suppress noise and preserve the image structure. Comparing with similar algorithms, the proposed algorithm greatly improves the peak signal-to-noise ratio (PSNR), structural similarity (SSIM), and root mean square error (RMSE) of the reconstructed image. The proposed algorithm has the best effect in quantitative analysis, which verifies the effectiveness of the proposed method and good image reconstruction performance. Overall, this study demonstrates that the proposed method can reduce the number of projections required for repeated CT scans and has potential for medical applications in reducing radiation doses. Show more
Keywords: X-ray computed tomography (CT), image reconstruction, total variation (TV), reduction of X-ray dose, reduction of image noise
DOI: 10.3233/XST-210906
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 5, pp. 797-812, 2021
Authors: Sun, Jihang | Li, Haoyan | Yang, Lixin | Zhou, Zuofu | Li, Michelle | Peng, Yun
Article Type: Research Article
Abstract: BACKGROUND: Low-tube voltage scanning improves CT attenuation value of contrast medium (CM). Thus, we hypothesized that 70 kVp in pediatric abdominal CT angiography (CTA) could be used to reduce both radiation and CM dose and improve patient comfort at the same time. OBJECTIVE: To evaluate the feasibility of using 70 kVp in pediatric abdominal CTA to reduce radiation dose and CM dose and improve patient care for children. MATERIALS AND METHODS: Forty-six children needing abdominal CTA were enrolled in the study group using low-dose scanning protocol with 70 kVp and 0.7–1.1 ml/kg contrast dose, and reconstructed with 50%ASIR-V. They were …compared with other 46 children in control group with matching body weight and underwent conventional CT scans with 100 kVp, 1.2–1.8 ml/kg contrast dose and reconstructed using 50%ASIR. Image quality of large vessels was evaluated using a 5-point scale. CT value and standard deviation of descending aorta (Ao) was measured, and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Radiation dose, contrast dose, the maximum injection pressure between the two groups were also compared. RESULTS: Score for displaying large vessels by 70 kVp images was 3.91±0.28, lower than that (4.17±0.38) of the control group (p < 0.05), but fully met the diagnostic requirements. CT value of Ao was 390.87±86.79HU in study group, which is higher than 343.93±49.94HU in control group, while there was no difference in SNR and CNR between two groups; the radiation dose, contrast dosage and injection pressure of the study group were 1.23±0.39mGy, 12.67±7.27 ml and 43.83±17.16psi, respectively, which are significantly lower than the 1.95±0.37mGy, 22.67±7.39 ml, and 77.59±19.68psi of control group. CONCLUSION: Use of 70 kVp in pediatric abdominal CTA provides diagnostic quality images while significantly reduce radiation and contrast dose, as well as injection pressure to improve patient comfort for children. Show more
Keywords: Computed tomography angiography (CTA), X-ray imaging, low voltage of X-ray tube, contrast medium, children
DOI: 10.3233/XST-210896
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 5, pp. 813-821, 2021
Authors: Pérez-Pelegrí, Manuel | Biarnés, Carles | Thió-Henestrosa, Santiago | Remollo, Sebastià | Gimeno, Alfredo | Cuba, Víctor | Teceño, Mikel | Martí-Navas, Marian | Serena, Joaquín | Pedraza, Salvador | Ruiz-Constantino, Juan Sebastián | Puig, Josep
Article Type: Research Article
Abstract: BACKGROUND AND OBJECTIVE: Estimates of parameters used to select patients for endovascular thrombectomy (EVT) for acute ischemic stroke differ among software packages for automated computed tomography (CT) perfusion analysis. To determine impact of these differences in decision making, we analyzed intra-observer and inter-observer agreement in recommendations about whether to perform EVT based on perfusion maps from 4 packages. METHODS: Perfusion CT datasets from 63 consecutive patients with suspected acute ischemic stroke were retrospectively postprocessed with 4 packages of Minerva, RAPID, Olea, and IntelliSpace Portal (ISP). We used Pearson correlation coefficients and Bland-Altman analysis to compare volumes of infarct …core, penumbra, and mismatch calculated by Minerva and RAPID. We used kappa analysis to assess agreement among decisions of 3 radiologists about whether to recommend EVT based on maps generated by 4 packages. RESULTS: We found significant differences between using Minerva and RAPID to estimate penumbra (67.39±41.37mL vs. 78.35±45.38 mL, p < 0.001) and mismatch (48.41±32.03 vs. 61.27±32.73mL, p < 0.001), but not of infarct core (p = 0.230). Pearson correlation coefficients were 0.94 (95%CI:0.90–0.96) for infarct core, 0.87 (95%CI:0.79–0.91) for penumbra, and 0.72 (95%CI:0.57–0.83) for mismatch volumes (p < 0.001). Limits of agreements were (–21.22–25.02) for infarct core volumes, (–54.79–32.88) for penumbra volumes, and (–60.16–34.45) for mismatch volumes. Final agreement for EVT decision-making was substantial between Minerva vs. RAPID (k = 0.722), Minerva vs. Olea (k = 0.761), and RAPID vs. Olea (k = 0.782), but moderate for ISP vs. the other three. CONCLUSIONS: Despite quantitative differences in estimates of infarct core, penumbra, and mismatch using 4 software packages, their impact on radiologists’ decisions about EVT is relatively small. Show more
Keywords: Acute ischemic stroke, computed tomography perfusion (CTP), endovascular thrombectomy (EVT), estimates of infarct core, penumbra and mismatch
DOI: 10.3233/XST-210898
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 5, pp. 823-834, 2021
Authors: Rezaeijo, Seyed Masoud | Ghorvei, Mohammadreza | Mofid, Bahram
Article Type: Research Article
Abstract: OBJECTIVE: To develop an ensemble a deep transfer learning model of CT images for predicting pathologic complete response (pCR) in breast cancer patients undergoing neoadjuvant chemotherapy (NAC). METHODS: The data were obtained from the public dataset ‘QIN-Breast’ from The Cancer Imaging Archive (TCIA). CT images were gathered before and after the first cycle of NAC. CT images of 121 breast cancer patients were used to train and test the model. Among these patients, 58 achieved a pCR and 63 showed a non-pCR based pathology examination of surgical results after NAC. The dataset was split into training and testing …subsets with a ratio of 7:3. In addition, the number of training samples in the dataset was increased from 656 to 1,968 by performing an image augmentation method. Two deep transfer learning models namely, DenseNet201 and ResNet152V2, and the ensemble model with a concatenation of two models, were trained and tested using CT images. RESULTS: The ensemble model obtained the highest accuracy of 100% on the testing dataset. Furthermore, we received the best performance of 100% in recall, precision and f1-score value for the ensemble model. This supports the fact that the ensemble model results in better-generalized model and leads to efficient framework. Although a 0.004 and 0.003 difference were seen between the AUC of two base models (DenseNet201 and ResNet152V2) and the proposed ensemble, this increase in the model quality is critical in medical research. T-SNE revealed that in the proposed ensemble, no points were clustered into the wrong class. These results expose the strong performance of the proposed ensemble. CONCLUSION: The study concluded that the ensemble model can increase the ability to predict breast cancer response to first-cycle NAC than two DenseNet201 and ResNet152V2 models. Show more
Keywords: Ensemble, deep transfer learning, breast, neoadjuvant chemotherapy, CT
DOI: 10.3233/XST-210910
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 5, pp. 835-850, 2021
Authors: Qiao, Zhiwei | Lu, Yang
Article Type: Research Article
Abstract: PURPOSE: Total Variation (TV) minimization algorithm is a classical compressed sensing (CS) based iterative image reconstruction algorithm that can accurately reconstruct images from sparse-view projections in computed tomography (CT). However, the system matrix used in the algorithm is often too large to be stored in computer memory. The purpose of this study is to investigate a new TV algorithm based on image rotation and without system matrix to avoid the memory requirement of system matrix. METHODS: Without loss of generality, a rotation-based adaptive steepest descent-projection onto convex sets (R-ASD-POCS) algorithm is proposed and tested to solve the TV …model in parallel beam CT. Specifically, simulation experiments are performed via the Shepp-Logan, FORBILD and real CT image phantoms are used to verify the inverse-crime capability of the algorithm and evaluate the sparse reconstruction capability and the noise suppression performance of the algorithm. RESULTS: Experimental results show that the algorithm can achieve inverse-crime, accurate sparse reconstruction and thus accurately reconstruct images from noisy projections. Compared with the classical ASD-POCS algorithm, the new algorithm may yield the similar image reconstruction accuracy without use of the huge system matrix, which saves the computational memory space significantly. Additionally, the results also show that R-ASD-POCS algorithm is faster than ASD-POCS. CONCLUSIONS: The proposed new algorithm can effectively solve the problem of using huge memory in large scale and iterative image reconstruction. Integrating with ASD-POCS frame, this no-system-matrix based scheme may be readily extended and applied to any iterative image reconstructions. Show more
Keywords: Rotation-based reconstruction, system matrix, TV minimization, iterative algorithm, computed tomography
DOI: 10.3233/XST-210929
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 5, pp. 851-865, 2021
Authors: Romero, Ignacio O. | Li, Changqing
Article Type: Research Article
Abstract: BACKGROUND: The time of flight (TOF) cone beam computed tomography (CBCT) was recently shown to reduce the X-ray scattering effects by 95% and improve the image CNR by 110% for large volume objects. The advancements in X-ray sources like in compact Free Electron Lasers (FEL) and advancements in detector technology show potential for the TOF method to be feasible in CBCT when imaging large objects. OBJECTIVE: To investigate the feasibility and efficacy of TOF CBCT in imaging smaller objects with different targets such as bones and tumors embedded inside the background. METHODS: The TOF method used …in this work was verified using a 24 cm phantom. Then, the GATE software was used to simulate the CBCT imaging of an 8 cm diameter cylindrical water phantom with two bone targets using a modeled 20 keV quasi-energetic FEL source and various TOF resolutions ranging from 1 to 1000 ps. An inhomogeneous breast phantom of similar size with tumor targets was also imaged using the same system setup. RESULTS: The same results were obtained in the 24 cm phantom, which validated the applied CBCT simulation approach. For the case of 8 cm cylindrical phantom and bone target, a TOF resolution of 10 ps improved the image contrast-to-noise ratio (CNR) by 57% and reduced the scatter-to-primary ratio (SPR) by 8.63. For the case of breast phantom and tumor target, image CNR was enhanced by 12% and SPR was reduced by 1.35 at 5 ps temporal resolution. CONCLUSIONS: This study indicates that a TOF resolution below 10 ps is required to observe notable enhancements in the image quality and scatter reduction for small objects around 8 cm in diameter. The strong scattering targets such as bone can result in substantial improvements by using TOF CBCT. Show more
Keywords: Time of flight (TOF), cone beam computed tomography (CBCT), Monte-Carlo Simulation, GATE software
DOI: 10.3233/XST-210918
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 5, pp. 867-880, 2021
Authors: Deng, Heping | Mi, Yaru | Lu, Bo | Xu, Ping
Article Type: Research Article
Abstract: OBJECTIVE: To explore the value of virtual touch imaging and quantification (VTIQ) shear wave elastography (SWE) in diagnosis of supraspinatus tendon tear. METHODS: Eighty patients with unilateral supraspinatus tendon tear underwent shoulder arthroscopy were prospective studied. Tendinopathy, partial-thickness tear or full-thickness tear of supraspinatus tendon were diagnosed according 2D ultrasound examination. Sensitivity, specificity and accuracy of ultrasonic diagnosis of supraspinatus tendon tear were calculated by arthroscopy as the gold standard. VTIQ was applied to measure the shear-wave velocity (SWV) of both normal and affected supraspinatus tendon. The differences of SWV in three types of supraspinatus tendon tear and …receiver operating characteristic (ROC) curves were analyzed. RESULTS: Among 80 patients, there were 20 tendinopathy, 31 partial tears and 29 full-thickness tears diagnosed by shoulder arthroscopy. Sensitivity, specificity and accuracy of 2D ultrasound in diagnosis of tendinopathy, partial tear and full-thickness tear groups were 78%, 90%and 83%; 71%, 86%and 73%; 86%, 88%and 88%, respectively. SWV of 80 supraspinatus tendon tears was 4.59±1.00 m/s, which was lower than that of normal supraspinatus tendon (4.59±1.00 m/s vs. 6.68±1.05 m/s, P < 0.01). SWV of supraspinatus tendon in tendinopathy, partial tear and full-thickness tear groups respectively were 5.66±0.97, 4.66±1.00, and 3.78±0.55 m/s, all lower than that of the contralateral normal supraspinatus tendon (all P < 0.05). In addition, the analysis of variance and pairwise comparison showed that SWV of supraspinatus tendon among three different degree of injury was statistically significant (all P < 0.001). The cutoff thresholds of SWV was 4.83 m/s to identify tendinopathy tear from partial tear and was 4.08 m/s to identify full-thickness tear from partial-thickness tear. CONCLUSION: VTIQ SWE with SWV might identify degree of supraspinatus tendon tear and improve the value of ultrasonography, which should be further evaluated in large multicenter studies. Show more
Keywords: Supraspinatus tendon tear, virtual touch imaging and quantification (VTIQ), ultrasonography, shear-wave velocity
DOI: 10.3233/XST-210865
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 5, pp. 881-890, 2021
Authors: Huang, Jingyu | Jiang, Shixie | Wagoner, Ryan | Yang, Hao | Currier, Glenn | Jiang, Huabei
Article Type: Research Article
Abstract: Repetitive transcranial magnetic stimulation (rTMS) of the brain is an effective clinical treatment for psychiatric disorders. Noninvasive neuroimaging during rTMS allows visualization of cortical brain activations and responses, and it is a potential tool for investigating the neurophysiological response occurring actively during stimulation. In this paper, we present a fast diffuse optical tomography (DOT) approach for three-dimensional brain mapping of hemodynamics during rTMS. Eight healthy subjects were enrolled in the study. These subjects received 10 Hz stimulation with 80%and 100%of resting motor threshold (rMT), respectively, for 4 seconds for each stimulation. Significant hemodynamic activation was observed in all cases with …the strongest response when 100%rMT stimulation was applied. This work demonstrates that fast DOT has the potential to become a powerful tool for noninvasive three-dimensional imaging of the brain during rTMS. Show more
Keywords: Diffuse optical tomography, noninvasive brain imaging, repetitive transcranial magnetic stimulation, healthy subjects
DOI: 10.3233/XST-210900
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 5, pp. 891-902, 2021
Authors: Xu, Wenjie | Tan, Hao | Meng, Xuehuan | Ming, Ye | Wang, Tao | Zheng, Leilei
Article Type: Research Article
Abstract: OBJECTIVE: To investigate three-dimensional soft tissue changes of lips and related jaw changes in patients with skeletal class III malocclusion and facial asymmetry using cone-beam computerized tomography (CBCT). METHOD: This study included 46 CBCT scans of patients with aforementioned character before (T1) and 6–12 months after orthognathic surgery (T2). Subjects were divided into 2 groups according to two types of orthognathic surgery namely, the one-jaw surgery group who underwent bilateral sagittal splint ramus osteotomy (BSSRO) and the two-jaw surgery group who underwent Le Fort I osteotomy and BSSRO. Mimics 19.0 software are used for model reconstruction, landmark location …and three-dimensional cephalometric analysis. Descriptive statistics and correlation analyses are used to investigate jaw hard tissue and lip soft tissue changes. RESULTS: In one-jaw group, the mandible shows changes in contour and position (p < 0.05), and the surgery causes changes of lip structure on the deviated side. While in two-jaw group, jaws only show changes in spatial position, and surgery changes contour of bilateral lips and nasolabial angle (p < 0.05). At the same time, lip symmetry increases significantly in both groups postoperatively. CONCLUSIONS: Orthognathic surgery can improve lip aesthetics in patients with skeletal class III malocclusion and facial asymmetry. However, changes induced by two surgical approaches are different. Surgeons should have a clear acquaintance with this difference to deal with different situations. Show more
Keywords: CBCT, 3D cephalometric analyses, class III malocclusion, facial asymmetry, lip profile
DOI: 10.3233/XST-210903
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 5, pp. 903-916, 2021
Authors: Majdaeen, Mehrsa | Dorri-Giv, Masoumeh | Olfat, Shaghayegh | Ataei, Gholamreza | Abedi-Firouzjah, Razzagh | Banaei, Amin | Ranjbar, Sahar
Article Type: Research Article
Abstract: OBJECTIVES: To evaluate skin dose differences between TPS (treatment planning system) calculations and TLD (thermo-luminescent dosimeters) measurements along with the dosimetric effect of applicator misplacement for patients diagnosed with gynecological (GYN) cancers undergoing brachytherapy. METHODS: The skin doses were measured using TLDs attached in different locations on patients’ skin in pelvic regions (anterior, left, and right) for 20 patients, as well as on a phantom. In addition, the applicator surface dose was calculated with TLDs attached to the applicator. The measured doses were compared with TPS calculations to find TPS accuracy. For the phantom, different applicator shifts were …applied to find the effect of applicator misplacement on the surface dose. RESULTS: The mean absolute dose differences between the TPS and TLDs results for anterior, left, and right points were 3.14±1.03, 6.25±1.88, and 6.20±1.97 %, respectively. The mean difference on the applicator surface was obtained 1.92±0.46 %. Applicator misplacements of 0.5, 2, and 4 cm (average of three locations) resulted in 9, 36, and 61%, dose errors respectively. CONCLUSIONS: The surface/skin differences between the calculations and measurements are higher in the left and right regions, which relate to the higher uncertainty of TPS dose calculation in these regions. Furthermore, applicator misplacements can result in high skin dose variations, therefore it can be an appropriate quality assurance method for future research. Show more
Keywords: Brachytherapy, gynecologic cancers, TLD dosimetry, TPS accuracy
DOI: 10.3233/XST-210911
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 5, pp. 917-929, 2021
Authors: Qu, Yujia | Wang, Yuanjun
Article Type: Research Article
Abstract: BACKGROUND: The corpus callosum in the midsagittal plane plays a crucial role in the early diagnosis of diseases. When the anisotropy of the diffusion tensor in the midsagittal plane is calculated, the anisotropy of corpus callosum is close to that of the fornix, which leads to blurred boundary of the segmentation region. OBJECTIVE: To apply a fuzzy clustering algorithm combined with new spatial information to achieve accurate segmentation of the corpus callosum in the midsagittal plane in diffusion tensor images. METHODS: In this algorithm, a fixed region of interest is selected from the midsagittal plane, and …the anisotropic filtering algorithm based on tensor is implemented by replacing the gradient direction of the structural tensor with an eigenvector, thus filtering the diffusion tensor of region of interest. Then, the iterative clustering center based on K-means clustering is used as the initial clustering center of tensor fuzzy clustering algorithm. Taking filtered diffusion tensor as input data and different metrics as similarity measures, the neighborhood diffusion tensor voxel calculation method of Log Euclidean framework is introduced in the membership function calculation, and tensor fuzzy clustering algorithm is proposed. In this study, MGH35 data from the Human Connectome Project (HCP) are tested and the variance, accuracy and specificity of the experimental results are discussed. RESULTS: Segmentation results of three groups of subjects in MGH35 data are reported. The average segmentation accuracy is 97.34%, and the average specificity is 98.43%. CONCLUSIONS: When segmenting the corpus callosum of diffusion tensor imaging, our method cannot only effective denoise images, but also achieve high accuracy and specificity. Show more
Keywords: Diffusion tensor, fuzzy clustering, Log Euclidean framework
DOI: 10.3233/XST-210928
Citation: Journal of X-Ray Science and Technology, vol. 29, no. 5, pp. 931-944, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]