Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Vince, D. Geoffrey; | Tbakhi, Abdelghani | Gaddipati, Ajeetkumar; | Cothren, Robert M. | Cornhill, J. Fredrick | Tubbs, Raymond R.
Affiliations: Whitaker Biomedical Imaging Laboratory, Department of Biomedical Engineering | Department of Clinical Pathology, The Cleveland Clinic Foundation, Cleveland, Ohio | Biomedical Engineering Center, The Ohio State University, Columbus, Ohio
Note: [] Corresponding author: D. Geoffrey Vince, Department of Biomedical Engineering, Mail Drop Wb3, The Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH 44195, USA. Tel.: +1 216 444 1211; Fax: +1 216 444 9198; Email: vince@ bme.ri.ccf.org.
Abstract: Formaldehyde fixatives have traditionally been used to preserve tissues as they impart excellent morphological preservation. Formaldehyde fixes tissue by cross linking, a process which can reduce the antigenicity of tissue and weakens the intensity of immunohistochemical stains. Preliminary studies have shown that Histochoice tissue fixative offers equal or greater staining intensity than neutral buffered formalin (NBF). This study compares these fixatives quantitatively and presents the results in unambiguous statistical terms. Tissue samples were collected, bisected, and fixed in NBF or Histochoice. The sections were stained with a total of 21 antibodies, and color images were collected. The hue, saturation, and value were determined for each positive pixel and an ANOVA performed. Small differences in hue were noted in 8 of 21 cases. Histochoice‐fixed tissue gave a greater mean saturation than NBF with 57.1% of the antibodies tested. No significant difference in the saturation was detected in 28.6% of the cases; NBF gave higher mean saturation levels with only 14.3% of the antibodies. Histochoice‐fixed tissue was found to give lower values in 66.7% of cases than those prepared with NBF, indicating darker staining. These results show that Histochoice produces staining intensity that is comparable, and in many cases superior, to formalin.
Keywords: Image analysis, fixation, immunohistochemistry, color analysis
Journal: Analytical Cellular Pathology, vol. 15, no. 2, pp. 119-129, 1997
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]