Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Morgan, Marie Vazquez | Allison, Steve | Duhon, Damian
Affiliations: Louisiana State University Health Sciences Center, School of Allied Health Professions, Program in Physical Therapy, Shreveport, LA, USA | Tri-State OCCFIT Physical Therapy Inc., Shreveport, LA, USA
Note: [] Address for correspondence: LSUHSC, School of Allied Health Professions, Department of Rehabilitation Sciences, Program in Physical Therapy, c/o Marie Vazquez Morgan PT PhD, 1450 Claiborne Ave, Shreveport, LA 71130, USA. Tel.: +1 318 813 2944; E-mail: [email protected]
Abstract: Objective:Functional Capacity Evaluations (FCEs) have been utilized by healthcare professionals for over twenty years to provide an objective assessment of an individual's ability to safely perform functional work activities. Biomechanical observations have been established as a reliable method of determining safe maximal performance levels during dynamic lift testing in FCEs. The purpose of this study is to evaluate heart rate (HR) responses between participants in two performance levels (biomechanical safe-maximal and sub-maximal) and to attempt to establish a minimum threshold for HR changes that should be expected during specific functional testing protocols within FCEs. Participants: Participants included 500 men and women aged 20 to 85 years whom were injured on the job. Methods: Variables measured included resting HR, pre-test HR, peak-HR, and resting blood pressure. Percent HR change was calculated for the safe-maximal and sub-maximal performance level groups. Results: Statistically significant differences (p=0.0000000306) were found in HR change from pre-test to peak HR between performance level groups. Conclusions: Statistically significant differences were found in percent change in pre-test to peak HR, between the safe-maximal and sub-maximal performance level groups. This study provides the foundation for further research in establishing appropriate minimum expected changes in HR during FCE testing allowing clinicians to make more confident judgments relative to performance level.
Keywords: Occupational health, cardiovascular response, dynamic lift capacity
DOI: 10.3233/WOR-2012-1348
Journal: Work, vol. 42, no. 2, pp. 253-257, 2012
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]