Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Barbosa, Celso J. | Teles, Crisaldo | Moreira, Leonardo M.; | Damião, Álvaro J. | de Lima, Carlos J.
Affiliations: Laboratório de Instrumentação Biomédica, Centro de Engenharia Biomédica, Universidade Camilo Castelo Branco, Parque Tecnológico de São José dos Campos, São José dos Campos, SP, Brazil | Universidade Federal de São João Del Rei, São João Del Rei, MG, Brazil | Laboratório de Medição de Superfícies Ópticas-LMSO-IEAv-CTA, São José dos Campos, São Paulo, SP, Brazil
Note: [] Corresponding author: Leonardo M. Moreira, Universidade Federal de São João Del Rei, São João Del Rei, Minas Gerais, Brazil. E-mail: [email protected].
Abstract: Optical techniques of photobiostimulation, which use transducer as lasers and LEDs, have been employed in the treatment of several diseases. The laser systems usually irradiate in a reduced area of the target biological tissue, presenting high cost of acquisition. Devices with a LED of “Surface Mount Device” (SMD) type have high angle of light emission, implying in intense decrease of the density of optical potency. Furthermore, the use of this device requires the utilization of a cooling system, which provokes an increase in the cost of this product. In the present work, it is suggested the application of a novel opto-mechanical device constituted by usual LEDs with package dimension of 5 mm of diameter, which presents significant efficient and very low cost. The arrangement of the geometric configuration of these LEDs is elaborated in such way that all units emit photons in a unique section of an specific area. An opto-mechanical system was developed, which includes seven LEDs, being that six of these LEDs are disposed in a specific angle around a unique central LED. It is important to notice that all the opto-mechanical system with seven LEDs emit light in a unique area. Besides, a methodology was employed to allow the verification of the distribution of light intensity upon this respective area. This arrangement allows that this novel device propitiate measurements of the degree of homogeneity of the light intensity in specific areas, which are accessed by the seven light emitting units. The potency employing LEDs in the red (visible) and near infrared regions were also measured, being that the result demonstrated the capability of clinical application in optical therapy of photobiostimulation, which was also used in a pilot test of clinical application.
Keywords: LEDs, photobiostimulation, opto-mechanical system
DOI: 10.3233/SPE-2012-0567
Journal: Spectroscopy, vol. 27, no. 1, pp. 9-18, 2012
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]