Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Shadgan, Babak | Stothers, Lynn | Macnab, Andrew
Affiliations: Bladder Care Centre, University of British Columbia, Vancouver, BC, Canada
Note: [] Corresponding author: Dr. Babak Shadgan, Muscle Biophysics Laboratory, VGH Research Pavilion, 611-828 W. 10th Ave., Vancouver, BC, V5Z 1L8 Canada. Tel.: +1 778 317 7618; Fax: +1 604 822 7591; E-mail: [email protected].
Abstract: The majority of in vivo applications of near infrared spectroscopic (NIRS) monitoring use transcutaneous optode placement over the tissue of interest. Invasive application of optodes is occasionally described for monitoring tissue too deep for transcutaneous study, principally in animal models, but sometimes in humans. Invasive fibre-optic probes have been developed for a range of other spectroscopic applications including some in vivo. We describe the design and feasibility testing in a human subject of a vaginal probe to extend the scope of recently developed techniques for NIRS monitoring in urology. Design criteria included: use of optodes and cables with dimensions compatible with appropriate overall probe size; dual channel capability (for simultaneous monitoring of bladder wall and urethral sphincter); secure interoptode separation at correct distance for required penetration; ease of insertion, orientation and avoidance of movement artifact. Components were obtained that met design criteria and allowed use of the probe connected to a commercial NIRS instrument. Iterative development established optimal interoptode distance and secure positioning of a probe that could be housed for in vivo study within a disposable vaginal speculum. The feasibility of monitoring changes in chromophore concentration in the bladder detrusor and urethral sphincter using this intravaginal probe was evident from four separate studies during voiding and a series of physiologic events (cough, Valsalva and Kiegel contractions) in a healthy female volunteer. This small series suggests that reproducible data free of movement artifact, with consistent patterns and magnitudes of chromophore change can be obtained with the probe designed.
Keywords: Chromophore concentration, fibre-optic probes, hemodynamics, near infrared spectroscopy, spectroscopic analysis, urology
DOI: 10.3233/SPE-2008-0367
Journal: Spectroscopy, vol. 22, no. 6, pp. 429-436, 2008
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]