Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Maqbool, M.; | Ahmad, Iftikhar
Affiliations: Department of Science and Mathematics, Mount Olive College, 634 Henderson Street, Mount Olive, NC 28365, USA | Department of Physics & Astronomy, Louisiana State University, 202 Nicholson Hall, Tower Dr. Baton Rouge, LA 70803-4001, USA
Note: [] Corresponding author: M. Maqbool, Department of Science and Mathematics, Mount Olive College, 634 Henderson Street, Mount Olive, NC 28365, USA. Tel.: +1 (919) 6587498; Fax: +1 (919) 6587898; E-mail: [email protected]
Abstract: Intense ultraviolet emission from gadolinium doped amorphous aluminum nitride thin films deposited on Si (111) substrate is studied with cathodoluminescence and photoluminescence. The purpose of the study is to find the merits or demerits of gadolinium ions if added intentionally or present as unintentionally added impurity in tissue compensators or collimators in radiation treatment planning. These films are deposited by reactive sputtering at liquid nitrogen temperature, using 100–200 W RF power, 5–8 mTorr nitrogen, and a metal target of aluminum and gadolinium. Thermal annealing was performed at a temperature of 900°C. A sharp ultraviolet peak is observed at 314 nm corresponding to 6P7/2→8S7/2 transition. The ultraviolet emission is intense enough to harm human tissues if it is used as tissue compensator. Intense ultraviolet emission is observable even if the concentration of gadolinium is less than 0.5%. Thermal annealing further enhances the intensity of ultraviolet emission, indicating that longer use of such tissue compensators or collimators containing gadolinium ions will provide more harm and damage to human body. Radiation Therapists, Oncologist and industries making tissue compensators and collimators are strongly suggested to test any compensator or collimator for gadolinium impurities.
Keywords: Gadolinium, cathodoluminescence, photoluminescence, ultraviolet emission, tissue damage, tissue compensator
Journal: Spectroscopy, vol. 21, no. 4, pp. 205-210, 2007
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]