Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Macnab, A.J. | Gagnon, R.E.
Affiliations: Department of Pediatrics, University of British Columbia, Vancouver, Canada
Note: [] Corresponding author: Prof. Andrew Macnab, Director, Critical Care Research Office, Room L317, Mail Box 80, Children's & Women's Health Centre, 4480 Oak St., Vancouver, BC, Canada V6H 3V4. Tel.: +1 (604) 875 3524; Fax: +1 (604) 875 2890; E-mail: [email protected].
Abstract: We used a living biological phantom to evaluate whether previously observed clinical differences in data collection between two similar near infrared spectrophotometers were due to technical design differences. A Somanetics INVOS-5100 was compared to a Hamamatsu NIRO-300. Both express the ratio of oxygenated hemoglobin to total hemoglobin concentration as a percentage, and both are intended for monitoring cerebral oxygenation status at the bedside. The living phantom simulated different bone densities and contained a low haematocrit solution of blood, intra-lipid, and saline, to which was added grower's yeast to alter oxygenation status. Results: In all trials, oxygen saturation decreased from 100% to 0% as the yeast consumed the available oxygen. In all trials the spectrometers were significantly correlated (range: r2=0.815 to 0.995, p<0.05 for r2>0.232). The NIRO-300 indicated oxygenation change 1 minute after addition of yeast, whereas the INVOS-5100 showed change after 5 minutes. Simulated bone thickness had almost no effect upon the NIRO-300, but did affect the INVOS-5100. Conclusion: In this study, the spectrophotometers had similar results consistent with the technical design differences: the INVOS-5100 does not report hemoglobin saturation change above 95% or below 15% while the NIRO-300 reports the full range from 100% to 0%.
Journal: Spectroscopy, vol. 19, no. 3, pp. 165-169, 2005
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]