Issue title: Second International Conference on Biomedical Spectroscopy: From the Bench to the Clinic, London, UK, 5–8 July, 2003
Article type: Research Article
Authors: Timonen, M.; | Kangasmäki, A.; | Savolainen, S.; ; | Heikkinen, S.; ;
Affiliations: Department of Radiology, Helsinki University Central Hospital, P.O. Box 340, FIN‐00029 HUS, Helsinki, Finland | Department Physical Sciences, University of Helsinki, P.O. Box 64, FIN‐00014, Helsinki, Finland | Department of Laboratory Diagnostics, Helsinki University Central Hospital, P.O. Box 580, FIN‐00029 HUS, Helsinki, Finland | Advanced Magnetic Imaging Centre, Helsinki University of Technology, FIN‐02015 HUT, Espoo, Finland
Note: [] Corresponding author: Sami Heikkinen, Department of Radiology, Helsinki University Central Hospital, P.O. Box 340, FIN‐00029 HUS, Helsinki, Finland. Tel.: +358 50 427 1450; Fax: +358 9 471 71342; E‐mail: [email protected].
Abstract: The quantification of boron neutron capture therapy (BNCT) 10B‐carrier, L‐p‐boronophenylalanine‐fructose complex (BPA–F) was studied with phantoms using 1H magnetic resonance spectroscopy sequences PRESS and STEAM at 1.5 and 3.0 T. The results show that typical attainable short echo times of clinical MRS sequences combined with long repetition time result in clinically acceptable quantification accuracy. However, the concentration ratios, which are essential for the treatment planning, can still be reliably measured by using small repetition times. Detection limits of BPA in aqueous phantoms at 1.5 and 3.0 T were evaluated using clinically acceptable measurement time of ∼10 min, two typical voxel sizes (153 and 203 mm3) and PRESS and STEAM sequences. The detection limits of BPA in phantom conditions were 0.7 (3.0 T) and 1.4 mM (1.5 T) for PRESS sequence with 203 mm3 voxel.
Journal: Spectroscopy, vol. 18, no. 2, pp. 133-142, 2004
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]