Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: First International Conference on Biomedical Spectroscopy: From molecules to men, Cardiff, UK, 7–10 July 2002, Part II
Article type: Research Article
Authors: Castanho, M.A.R.B.; ; | Lopes, S. | Fernandes, M.
Affiliations: Departamento de Química e Bioquímica, Faculdade de Ciências da Universidade de Lisboa, Campo Grande C8, 1749‐016 Lisboa, Portugal | Centro de Química Física Molecular, Complexo I, Instituto Superior Técnico, Av. Rovisco Pais, 1049‐001 Lisboa, Portugal | Departamento de Química Física, Universidad de Murcia, 30071 Murcia, Spain
Note: [] Corresponding author. Tel.: +351 21 7500931; Fax +351 21 7500088; E‐mail: [email protected].
Abstract: Linear dichroism methodologies are based on the different interaction of molecules with linearly polarized light depending on their orientation. Theoretical predictions are used to conclude on the orientation of selected molecules relative to their neighbours (usually an organized matrix). In the specific case of linear dichroism methodologies applied to data obtained from UV‐Vis. spectroscopic techniques, the orientational distribution function of the chromophores' electronic transition moment can be calculated and converted to the molecular axis distribution function. In this paper, the orientation of molecular probes and biomolecules in model systems of biomembranes (lipidic matrixes) is explored and illustrated using common membrane probes (trans‐parinaric acid, a cyanine and laurdan) and polyene antibiotics (Amphotericin B and Nystatin). The emphasis is on the technique and methodologies themselves, rather than the scientific impact of the attained distributions. The main addressed items are: (1) How to adapt a common UV‐Vis. spectrophotometer and spectrofluorimeter to perform linear dicrhoism experiments?, (2) Sample preparation, and (3) Data analysis (including artefacts corrections).
Journal: Spectroscopy, vol. 17, no. 2-3, pp. 377-398, 2003
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]