Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Tanaka, H. | Xuan, L.J. | Morimoto, S. | Shoyama, Y.; | Isobe, R. | Nojima, K.
Affiliations: Department of Pharmacognosy, Faculty of Pharmaceutical Sciences, Kyushu University, 3‐1‐1 Maidashi, Higashi‐ku, Fukuoka 812, Japan | Department of Industrial Chemistry, Towa University, 1‐1‐1 Chikushigaoka, Minami‐ku, Fukuoka 815, Japan | MS Application Laboratory, Application and Research Centre, Analytical Instruments Division, JEOL LTD., 1‐2 Musashino, Akisima, Tokyo 196, Japan
Note: [] Corresponding author. Tel.: +81 92 642 6580; Fax: +81 92 642 6545; E‐mail: [email protected]‐u.ac.jp.
Abstract: Opium alkaloids were conjugated with bovine serum albumin (BSA) to give individual antigen conjugates which were analyzed using BSA as an internal standard by matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry. It became clear that 9 molecules of thebaine were conjugated in a thebaine–BSA conjugate. Codeine and morphine contents in individual conjugates were determined to be 12 and 6 molecules, respectively. Using a relative molecular mass of BSA, 11.5 molecules of forskolin conjugated with BSA. Tetrahydrocannabinolic acid (THCA)–carrier protein conjugates using β‐alanine or without β‐alanine as a linker were analyzed. From these results it became evident that the hapten molecules of THCA–β‐alanine–BSA, THCA–BSA, THCA–β‐alanine–human serum albumin (HSA) and THCA–HSA were 17.2, 12.7, 27.8 and 54.4, respectively. Crocin–HSA conjugates were synthesized by two methods using succinate and NaIO4 cleavage of sugar moiety. A broad molecular peak of crocin–HSA conjugate appeared at around m/z 98,342 resulting in 30 molecules of crocin‐hemisuccinate conjugated with HSA. The crocin–HSA synthesized via NaIO4 oxidation showed a sharp molecular peak around 69,504 compared to that of hemisuccinate preparation. The number of crocin combined with HSA was, however, smaller 3.1 molecules. Analysis of monoclonal antibody by MALDI mass spectrometry determined the exact molecular weight and their purities.
Journal: Spectroscopy, vol. 15, no. 1, pp. 1-18, 2001
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]