Issue title: Robot-Assisted Therapy: A Clinical Perspective
Guest editors: Hermano Igo Krebs
Article type: Research Article
Authors: Tanabe, Shigeoa; * | Hirano, Satoshib | Saitoh, Eiichib
Affiliations: [a] Faculty of Rehabilitation, School of Health Sciences, Fujita Health University, Aichi, Japan | [b] Department of Rehabilitation Medicine I, School of Medicine, Fujita Health University, Aichi, Japan
Correspondence: [*] Address for correspondence: Shigeo Tanabe, 98-1 Dengakugakubo, Kutsukake, Toyoake, Aichi, 470-1192, Japan. Tel.: +81 562 93 9000; Fax: +81 562 95 6817; E-mail: [email protected]
Abstract: Background:Due to physical and psychosocial issues associated with long-term sitting in a wheelchair, devising new ways to facilitate upright mobility is a key issue in rehabilitation medicine. Wearable Power-Assist Locomotor (WPAL) is a motorized orthosis and is developed for providing independent and comfortable walking for paraplegic patients. Methods:The WPAL consists of a wearable robotic orthosis and custom walker. To facilitate alternate usage with a wheelchair, the wearable robotic orthosis is based on a medial system with motors located at the bilateral hip, knee and ankle joints to reduce the increase in heart rate during gait. The gait parameters include stride length, toe clearance height, swing time, double support time, etc. (gait speed: up to 1.3 km/h). Independent gait with the walker can be learned through a five-stage gait exercise sequence. The first two stages are stepping and gait exercises with parallel bars. The third stage is gait exercise on treadmill. The subsequent two stages are gait exercise with walker. Results:Seven motor-complete paraplegic patients (spinal cord functional levels: T6-T12) participated. Through a series of exercises, all users achieved independent gait on a level floor (Functional Ambulation Categories: 4). The mean duration and distance of consecutively walking were 14.1 ± 11.4 minutes and 165.6 ± 202.6 m, respectively. The most competent user was able to walk continuously for as long as 40 minutes and 640 m whereas only for 6 minutes and 107 m with a conventional orthosis. Conclusions:These results suggest that WPAL might be useful device for supporting upright walking in persons with paraplegia.
Keywords: Spinal cord injury, gait rehabilitation, rehabilitation robotics, motorized orthosis
DOI: 10.3233/NRE-130932
Journal: NeuroRehabilitation, vol. 33, no. 1, pp. 99-106, 2013
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]