Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Nsenga Leunkeu, Angelinea; * | Lelard, Thierrya | Shephard, Roy J.b | Doutrellot, Pierre-Louisc | Ahmaidi, Saida
Affiliations: [a] Laboratoire de Recherche EA: 3300 “Adaptations Physiologiques á l'Exercice et Réadaptation á l'Effort”, Faculté des Sciences du Sport, Université de Picardie Jules Verne, Amiens, France | [b] Faculty of Kinesiology and Physical Education, University of Toronto, Toronto, ON, Canada | [c] Service d'Explorations Fonctionnelles de l'appareil locomoteur, Centre Hospitalier Universitaire (CHU) Nord, Amiens, France
Correspondence: [*] Address for correspondence: Angeline Nsenga Leunkeu, Ph.D., Faculté des Sciences du Sport, Université de Picardie Jules Verne, 80025, Amiens, France. Tel.: +33 3 22 82 79 03; Fax: +33 3 22 82 79 10; E-mail: [email protected]
Abstract: Background:Gait cycle and pressure distribution patterns can now be recorded quite simply and reproducibly with inexpensive in-sole pressure recorders. However, it is not known whether such readings are sufficiently stable to provide useful information in monitoring children with spastic hemiplegic cerebral palsy (HCP). Objective:The aim of this study was to asses the reproducibility of gait cycle and plantar pressure in HCP. Methods:Fourteen children with HCP (Gross Motor Function Classification System level I or II) undertook two walking trials (4 × 12 meters at self-selected speeds) with a one-week inter-test interval. Spatio-temporal gait cycle parameters and peak plantar pressures were measured at each visit, using Parotec in-shoe pressure sensors. Results:In the unaffected limb, satisfactory reproducibility was found for measurements of velocity, step frequency, time of double support, and step duration, but not for step amplitude or contact time. However, in the affected limb, only velocity and step duration showed moderate reproducibility. Likewise, all of 8 pressure measurements were reproducible for the unaffected limb, but pressures for the affected limb were only consistent at 4 sites (metatarsals 4-5, lateral heel, lateral mid-foot and hallux). Conclusions:Since plantar pressures are unstable only in the affected limb, the cause of variation is likely immediate spasm during movement of this limb rather than a more permanent change of posture. Some spatio-temporal parameters and plantar pressure readings have sufficient stability in both unaffected and affected limbs to allow their use when evaluating gait and planning therapy for children with HCP.
Keywords: Bland-Altman tests, children, hemiplegic cerebral palsy, rehabilitation, gait cycle, peak plantar pressures
DOI: 10.3233/NRE-141155
Journal: NeuroRehabilitation, vol. 35, no. 3, pp. 597-606, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]