Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Motor Rehabilitation – Part II
Guest editors: Volker Dietz
Article type: Research Article
Authors: Keller, Thierrya; * | Curt, Armina | Popovic, Milos R.b | Signer, Anneliesa | Dietz, Volkera
Affiliations: [a] Swiss Paraplegic Center, University Hospital Balgrist, Forchstrasse 340, CH-8008 Zurich, Switzerland | [b] Automatic Control Laboratory, Swiss Federal institute of Technology, Zurich, Switzerland
Correspondence: [*] Corresponding author. Tel.: + 41 1 3863736; Fax: + 41 1 3863909; E-mail: [email protected].
Abstract: A four channel functional electrical stimulation system with surface electrodes was developed and tested to give individuals with complete C4 and C5 tetraplegia a possibility to perform a grasping function. The proposed neuroprosthesis is EMG controlled, and it is voluntarily activated using the deltoid muscle of the contralateral arm. The duration of the processed above the threshold EMG signal was used to control the duration of the grasp, and the amplitude of the EMG signal was used to control the grasp strength. The following are the benefits of the proposed system: (1) restoration of the lost grasping function; (2) natural and easy to train control of hand opening and closing; (3) smooth adjustment of the grasping force; (4) a subject can use natural control strategies to control the prosthesis; and (5) the control algorithm is easy to integrate into a micro-controller device. Functional tests with a subject with C4 to C5 complete tetraplegia showed that the system significantly increased the subject’s independence in performing everyday tasks. The limiting factor for using the proposed neuroprosthesis was the fatigue of the proximal arm muscles. Surprisingly, the fatigue of the finger flexors, finger extensors and the contralateral arm deltoid muscles were not the limiting factor. Note that the deltoid muscle of the contalateral arm was used to control the prosthesis.
Keywords: Rehabilitation, Functional electrical stimulation (FES), EMG control, Grasping, Tetraplegia
DOI: 10.3233/NRE-1998-10305
Journal: NeuroRehabilitation, vol. 10, no. 3, pp. 251-255, 1998
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]