Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Mantokoudis, Georgiosa; b | Saber Tehrani, Ali S.b | Wozniak, Amyc | Eibenberger, Karind | Kattah, Jorge C.e | Guede, Cynthia I.e | Zee, David S.b | Newman-Toker, David E.b; *
Affiliations: [a] University Department of Otorhinolaryngology, Head and Neck Surgery, Inselspital Bern, Switzerland | [b] Department of Neurology, Johns Hopkins University School of Medicine, Baltimore, MD, USA | [c] Johns Hopkins Biostatistics Center, Baltimore, MD, USA | [d] Department of Otolaryngology – Head and Neck Surgery, Johns Hopkins University School of Medicine, Baltimore, MD, USA | [e] Department of Neurology, Illinois Neurologic Institute, University of Illinois, College of Medicine, Peoria, IL, USA
Correspondence: [*] Corresponding author: David E. Newman-Toker, MD PhD, Associate Professor, Department of Neurology, Johns Hopkins University School of Medicine, Johns Hopkins Hospital, CRB-II, Room 2M-03 North, 1550 Orleans Street, Baltimore, MD 21231, USA. Tel.: +1 443 287 9593; Fax: +1 410 502 7869; E-mail: [email protected].
Abstract: OBJECTIVE: The video head impulse test (HIT) measures vestibular function (vestibulo-ocular reflex [VOR] gain – ratio of eye to head movement), and, in principle, could be used to make a distinction between central and peripheral causes of vertigo. However, VOG recordings contain artifacts, so using unfiltered device data might bias the final diagnosis, limiting application in frontline healthcare settings such as the emergency department (ED). We sought to assess whether unfiltered data (containing artifacts) from a video-oculography (VOG) device have an impact on VOR gain measures in acute vestibular syndrome (AVS). METHODS: This cross-sectional study compared VOG HIT results ‘unfiltered’ (standard device output) versus ‘filtered’ (artifacts manually removed) and relative to a gold standard final diagnosis (neuroimaging plus clinical follow-up) in 23 ED patients with acute dizziness, nystagmus, gait disturbance and head motion intolerance. RESULTS: Mean VOR gain assessment alone (unfiltered device data) discriminated posterior inferior cerebellar artery (PICA) strokes from vestibular neuritis with 91% accuracy in AVS. Optimal stroke discrimination cut points were bilateral VOR gain >0.7099 (unfiltered data) versus >0.7041 (filtered data). For PICA stroke sensitivity and specificity, there was no clinically-relevant difference between unfiltered and filtered data–sensitivity for PICA stroke was 100% for both data sets and specificity was almost identical (87.5% unfiltered versus 91.7% filtered). More impulses increased gain precision. CONCLUSIONS: The bedside HIT remains the single best method for discriminating between vestibular neuritis and PICA stroke in patients presenting AVS. Quantitative VOG HIT testing in the ED is associated with frequent artifacts that reduce precision but not accuracy. At least 10–20 properly-performed HIT trials per tested ear are recommended for a precise VOR gain estimate.
Keywords: Eye movement measurements, vestibulo-ocular reflex, vertigo, vestibular neuritis, stroke, diagnosis
DOI: 10.3233/VES-160587
Journal: Journal of Vestibular Research, vol. 26, no. 4, pp. 375-385, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]