Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Nowé, Vickya | Wuyts, Floris L.b; c; * | Hoppenbrouwers, Miekeb | Van de Heyning, Paul H.b | De Schepper, Arthur M.a | Parizel, Paul M.a
Affiliations: [a] Department of Radiology, Universitair Ziekenhuis Antwerpen, University of Antwerp, Antwerpen, Belgium | [b] Department of ENT, Universitair Ziekenhuis Antwerpen, University of Antwerp, Antwerpen, Belgium | [c] Department of Biomedical Physics, University of Antwerp, Antwerpen, Belgium
Correspondence: [*] Correspondence: F.L. Wuyts, PhD, Professor in Medical Physics and Biomedics, Head of the Vestibular Function Lab, Dept. of Biomedical Physics – Dept. of Otolaryngology, University of Antwerp, Wilrijkstraat 10, B-2650 Edegem, Belgium. Tel.: +32 486 63 75 50; E-mail: [email protected]
Abstract: Knowledge of the exact distance between the utricles is important in new vestibular tests, such as the unilateral centrifugation (UC) test for the unilateral examination of the utricles. During this test, subjects are rotated at constant velocity and simultaneously laterally displaced along an interaural axis so that one labyrinth becomes aligned with the axis of rotation. When the axis of rotation crosses precisely through one labyrinth, only the opposite labyrinth is stimulated. To achieve this setup, precise knowledge of the interutricular distance is needed. The purpose of this study is to investigate the correlation between the interutricular distance (IUD), measured on T2-weighted magnetic resonance images, and specific external measures of head dimensions such as distance nasion-inion, intermastoid distance (IMD), distances between the temporomandibular joints and between the lateral margins of the orbits. Data have been collected in a series of 50 subjects (25 men and 25 women). On MR images we found a mean IUD of 7.22 cm (SD=0.42 cm). There was a strong correlation between the IUD measured on MR images and the intermastoid distance. A linear combination of the IMD, nasion-inion distance and height of the subjects could predict the IUD very satisfactory (R=0.85, adjusted R2=0.723). We also determined a measure of eccentricity of the vestibular labyrinths. The 95% prediction interval for the asymmetry appeared to be less than 4.3%.
DOI: 10.3233/VES-2003-13103
Journal: Journal of Vestibular Research, vol. 13, no. 1, pp. 17-23, 2003
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]