Article type: Research Article
Authors: Taghipour-Darzi, Mohammada; * | Ebrahimi-Takamjani, Esmailb | Salavati, Mahyarc | Mobini, Bahramd | Zekavat, Hajare
Affiliations: [a] Department of Physiotherapy, Faculty of Medicine, Babol University of Medical Sciences, Babol, Mazandaran, Iran | [b] Department of Physiotherapy, Faculty of Rehabilitation, Iran University of Medical Sciences, Tehran, Iran | [c] Department of Physiotherapy, University of Social Welfare and Rehabilitation, Tehran, Iran | [d] Orthopedic Department, Iran University of Medical Sciences, Tehran, Iran | [e] Department of Radiology, Iran University of Medical Sciences, Tehran, Iran
Correspondence: [*] Address for correspondence: Mohammad Taghipour-Darzi (PhD, PT), Assistant Professor, Department of Physiotherapy, Faculty of Medicine, Babol University of Medical Sciences, Babol, Mazandaran, Iran, 47176-47745. Tel.: +98 111 3290515; Fax: +98 111 2229936; E-mail: [email protected]
Abstract: Background data:For center of rotation (COR) and centroid length variables in lumbar flexion-extension radiography, enough reliability information is not available. Objective:The objective of this study was to determine the intra-rater reliability of COR and centroid length of lumbar intervertebral movement. Methods:A methodological research for reliability was designed. Fifteen males with chronic non specific low back pain aged between 22–43 years participated in this study. Study variables included COR of full, flexion and extension arc and centroid length. The proposed method from Putto was used for flexion-extension radiography. Five x-rays were taken in neutral, full flexion and extension, mid-flexion and mid-extension positions. The variables were calculated using Computer Aided Radiographic Analysis of Spine (CARA) software after scanning. The intraclass correlation coefficient (ICC) and standard error of measurement (SEM) were utilized for relative and absolute reliability respectively. Results:The results demonstrated high ICC values on x axis (range: 0.67–0.88) and y axis (range: 0.55–0.90) for full arc COR, high ICC values of flexion arc COR on x axis (range: 0.54–0.97) and y axis (range: 0.48–0.99). ICC values results of extension arc ranged between 0.19–0.60 for x axis and 0.16–0.83 for y axis. ICC values for centroid length ranged between 0.22–0.88. Conclusion:Results support previous studies which show very high reliability of full arc COR. In addition, flexion arc COR has desirable reliability and low measurement errors. But, extension arc COR and centroid length have moderate reliability and large measurement errors.
Keywords: Reliability, flexion-extension radiography, quality of motion, lumbar segmental instability
DOI: 10.3233/BMR-2009-0228
Journal: Journal of Back and Musculoskeletal Rehabilitation, vol. 22, no. 3, pp. 149-156, 2009
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]