Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Tousignant, M.a; * | Morissette, J.b | Murphy, M.b
Affiliations: [a] Gerontology and Geriatrics Research Center, Sherbrooke Geriatric University Institute, Quebec, Canada | [b] University of Ottawa and Outaouais Physiotherapy Clinic
Correspondence: [*] Address for correspondence: M. Tousignant, PhD, Research Center on Aging, Sherbrooke Geriatric University Institute, 1036 Belvédère Sud, Sherbrooke, Québec, J1H 4C4, Canada. Tel.: +1 819 821 1170 ext. 2351; Fax: +1 819 829 7141; E-mail: michel. [email protected]
Abstract: Purpose:The purpose was to estimate the criterion validity of the Back Range of Motion (BROM II) and Electronic Digital Inclinometer (EDI-320) devices. METHODS. This study compared the range of motion measurements of low back pain (LBP) patients taken with the BROM II and EDI-320 with measurements using the double inclinometer (DI) method as the gold standard. Forty subjects with LBP volunteered for the study. The subjects were asked to do three forward flexion movements. A measurement was taken with each of the three different devices for each movement. Results:The BROM II demonstrated good linear relationship (Pearson r = 0.78; 95% CI: 0.78–0.94) and the EDI-320 very good linear relationship (Pearson r = 0.88; 95% CI: 0.62–0.89) with the gold standard, the DI. Conclusions:The Pearson correlation value indicates good validity of the EDI-320 in our sample of LBP patients. Although a good correlation was established for the BROM II, the significant difference of the mean ROM reported for this instrument compared to the gold standard data suggests that the BROM II actually measures ROM differently. Our results suggest that the EDI 320 is clinically useful in providing objective and valid data for outcome measures in a population with LBP. More research is needed on the BROM II before we can make final conclusion on its use in clinical settings as an outcome measure.
Keywords: low back pain, range of motion, measurement, validity, outcome measure
DOI: 10.3233/BMR-2002-16407
Journal: Journal of Back and Musculoskeletal Rehabilitation, vol. 16, no. 4, pp. 159-167, 2002
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]