Abstract: There is a growing literature concerning chondrocyte responses to mechanical loading, but relatively little is known about the mechanical environment these cells experience in a living joint. Calculations indicate that high forces are applied to limb joints whenever the joints are flexed, because flexion can cause body weight to act on long lever arms compared to the joint centre, whereas the muscles which extend the joint act on much shorter lever arms. As a result, joint reaction forces (which compress the cartilage) can rise to 3–6 times body weight during activities such as stair climbing. Articular cartilage tends to spread this load evenly over the joint surface, but is too thin to do this well, and compressive stresses can rise to 10–20 MPa. Within cartilage, matrix stresses vary locally, possibly as a result of variation in composition or undulations in the subchondral bone, and further modifications of stress occur within each chondron. Articular cartilage is a fibrous solid and cells within it are deformed by mechanical loading rather than subjected to a hydrostatic pressure. The mechanical environment of chondrocytes can best be reproduced in vitro by direct compression of the articular surface of cartilage which is supported naturally by adjacent cartilage and subchondral bone.
Keywords: Cartilage, mechanics, mechanobiology, matrix, stress
Journal: Biorheology, vol. 43, no. 3-4, pp. 537-545, 2006
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]